Rapid Determination of Hydrogen Peroxide in Milk with Non‐enzymatic Amperometric Sensor Based on Porous Gold Modified Screen‐printed Electrode in Online Dialysis System
- 8 July 2022
- journal article
- research article
- Published by Wiley in Electroanalysis
- Vol. 35 (2)
Abstract
A rapid method for determination of hydrogen peroxide based on a non‐enzymatic amperometric sensor with an online dialysis unit was developed for analysis of sample with complicated matrices. A porous gold modified gold screen‐printed electrode was prepared by a simple method using 9 V‐battery electrodeposition. Based on data from amperometry, a linear dynamic range can be obtained in the range of 10 to 1000 μmol L−1, with a limit of detection of 0.37 μmol L−1. The proposed system was successfully applied to determine H2O2 in various milk samples with rapid analysis, high electrode stability, and excellent repeatability (1.95 % RSD with 100 replications).Keywords
This publication has 44 references indexed in Scilit:
- A non-enzymatic sensor for hydrogen peroxide based on polyaniline, multiwalled carbon nanotubes and gold nanoparticles modified Au electrodeThe Analyst, 2011
- Fast and Accurate Analysis of Drugs Using Amperometry Associated With Flow Injection AnalysisJournal of Pharmaceutical Sciences, 2010
- Fluorometric determination of hydrogen peroxide in milk by using a Fenton reaction systemFood Chemistry, 2010
- Determination of hydrogen peroxide residues in aseptically packaged beverages using an amperometric sensor based on a palladium electrodeFood Control, 2008
- Fabrication, properties and application of porous metals with directional poresProgress in Materials Science, 2007
- Nanoporous Metal (Cu, Ag, Au) Films with High Surface Area: General Fabrication and Preliminary Electrochemical PerformanceThe Journal of Physical Chemistry C, 2007
- Synthesis of porous copper from nanocrystalline two-phase Cu–Zr film by dealloyingScripta Materialia, 2007
- Preservation of raw milk by activation of the natural lactoperoxidase systemsFood Control, 1996
- Automated determination of lactulose in milk using an enzyme reactor and flow analysis with integrated dialysisAnalytica Chimica Acta, 1996
- Folic acid stability in hydrogen peroxide-potassium thiocyanate-treated milkFood Chemistry, 1992