Pseudo Cavity of Schiff Base Ionophore Incorporated in Screen Printed Electrode for Sensing of Zn (II)
Authors:
- 8 April 2019
- journal article
- research article
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 166 (6) , B464-B471
Abstract
An electrochemical sensor for Zn2+ ions in aqueous medium has been developed using disposable screen printed electrodes (SPE). Working electrode of the screen printed electrode has been modified using an ionophore (SMS-3) having schiff base moiety. Surface modification and redox behavior of the SMS-3 modified SPE has been compared with unmodified SPE using Scanning Electron Microscopy (SEM) and Cyclic Voltammetry (CV). Herein, we discovered that modified SPE showed good electrochemical signals and sensitivity toward metal ions. The characteristic cathodic peaks at −0.59 V and 0.55 V of the ionophore was quenched in the presence of Zn2+. SMS-3 modified SPE works in the detection range of 0.47 to 5.56 μM with a limit of detection (LOD) 0.92 μM. DFT studies on SMS-3 supported the observations for the modified SPE. Further, sensitivity and selectivity of the electrode were also examined in the presence of various interfering ions and found that these ions did not interfere in the detection of Zn2+ ions. The electrodes were applied for the detection of Zn2+ in food samples.Keywords
This publication has 58 references indexed in Scilit:
- New molecular probe for the selective detection of zinc ionThe Analyst, 2013
- Preconcentration and separation of copper, nickel and zinc in aqueous samples by flame atomic absorption spectrometry after column solid-phase extraction onto MWCNTs impregnated with D2EHPA-TOPO mixtureJournal of Hazardous Materials, 2011
- Both Visual and Fluorescent Sensor for Zn2+ Based on Quinoline PlatformInorganic Chemistry, 2010
- ZINC AND THE RISK FOR INFECTIOUS DISEASEAnnual Review of Nutrition, 2004
- Electroanalytical Determination of Zinc in Human Blood Facilitated by Acoustically Assisted Double ExtractionElectroanalysis, 2004
- Stripping chronopotentiometric detection of copper using screen-printed three-electrode system—application to acetic-acid bioavailable fraction from soil samplesAnalytica Chimica Acta, 2003
- Zn(II)-selective membrane electrode based on tetra(2-aminophenyl) porphyrinAnalytica Chimica Acta, 2002
- Evaluation of miniaturised solid state reference electrodes on a silicon based componentSensors and Actuators B: Chemical, 1997
- Quick-Change Pathogens Gain an Evolutionary Edge1996
- Self-Consistent Equations Including Exchange and Correlation EffectsPhysical Review B, 1965