Evaluation of wearable IMU performance for orientation estimation and motion tracking
Authors:
- 1 June 2018
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-6
Abstract
Introducing objective wearable IMU measurements of functional movement quality into clinical assessments may improve accuracy of diagnosis. The goal of the present study was to assess the performance of inexpensive wearable IMUs relative to conventional motion capture equipment during controlled movements that are representative of typical human movement. Thirty-five cycles of spine flexion-extension, lateral bending, and axial twisting were simulated by means of a motorized gimbal at speeds of 20 cycles/min and 40 cycles/min. Differences between cycle-to-cycle maximum angle, minimum angle, and ROM values, as well as correlational analyses within IMUs and between IMUs and motion capture, in all movement directions, were compared. All absolute differences in measurements were <; 1.55°. There were very high correlations between repeated IMU measures (R > 0.99) in all movement directions showing reliability between sensors and measurements. Overall, it was revealed that the sensors perform very well in the primary movement direction and one secondary axis; however, correlation in the third axis is suboptimal for orientation estimation and motion tracking.Keywords
This publication has 22 references indexed in Scilit:
- Inertial Measures of Motion for Clinical Biomechanics: Comparative Assessment of Accuracy under Controlled Conditions - Effect of VelocityPLOS ONE, 2013
- Local dynamic stability of trunk movements during the repetitive lifting of loadsHuman Movement Science, 2012
- The use of inertial sensors system for human motion analysisPhysical Therapy Reviews, 2010
- The reliability of three-dimensional kinematic gait measurements: A systematic reviewGait & Posture, 2009
- Trunk posture monitoring with inertial sensorsEuropean Spine Journal, 2008
- Human motion tracking for rehabilitation—A surveyBiomedical Signal Processing and Control, 2008
- A method for manipulating a movable platform's axes of rotation: A novel use of the CAREN systemGait & Posture, 2006
- Stability of Dynamic Trunk MovementSpine, 2006
- A new ambulatory system for comparative evaluation of the three‐dimensional knee kinematics, applied to anterior cruciate ligament injuriesKnee Surgery, Sports Traumatology, Arthroscopy, 2006
- Diagnosis and classification of chronic low back pain disorders: Maladaptive movement and motor control impairments as underlying mechanismManual Therapy, 2005