Abstract
The use of biodegradable polymers in biomedical applications has been successful in nonload bearing applications, such as biodegradable implants for local drug delivery, and in simple load bearing situations such as surgical sutures and orthopedic fixation screws. The desire to incorporate these materials in more complex load bearing situations, such as tissue engineering scaffolds and endovascular or urethral stents, is strong, but the lack of constitutive models describing the evolution of biodegradable polymers over the course of degradation has severely hampered the rational design process for these more complex biodegradable medical applications. With the objective of predicting biodegradable stent behavior, we incorporated constitutive models of biodegradable polymeric materials in a computational setting and the mechanical response of three different stent designs were analyzed as degradation progressed. A thermodynamically consistent constitutive model for materials undergoing deformation-induced degradation was applied to a commonly employed biodegradable polymer system, poly(L-lactic acid), and its specific form was determined by corroboration against experimental data. Depreciation of mechanical properties due to degradation confers time-dependent characteristics to the response of the biodegradable material: the deformation imparted by a constant load increases over time, i.e. the body creeps, and the stress necessary to keep a fixed deformation decreases, i.e. the body relaxes. Biodegradable stents, when subjected to constant pressure in its exterior, deflect inwards and ultimately fail as the structure loses its mechanical integrity. The complex geometry of endovascular stents and their physiological loading conditions lead to inhomogeneous deformations, and consequently, inhomogeneous degradation ensues. Degradation is mostly confined to the bends of the stent rings and junction points, which are the locations that carry most of the deformation, whereas mostly undeformed connector bars remain less degraded. If failure occurs, it will occur most likely at those sensitive locations and large, nondegraded pieces can provoke severe embolic problems. Highly nonuniform degradation indicates that some stent designs are at higher risk for complications. Deformation patterns of stents made of a material that loses its integrity are different than those of permanent stents. Blind adaptation of permanent stent design concepts is ill-suited for biodegradable stent design. The time-dependent aspect of the implant not only must be taken into account but should also be used to interact with the body’s reaction and to enhance healing.Keywords
This publication has 56 references indexed in Scilit:
- Deformation-induced hydrolysis of a degradable polymeric cylindrical annulusBiomechanics and Modeling in Mechanobiology, 2009
- Biomechanical Issues in Endovascular Device DesignJournal of Endovascular Therapy, 2009
- Diffusion of a fluid through a spherical elastic solid undergoing large deformationsInternational Journal of Engineering Science, 2009
- Intracranial and Abdominal Aortic Aneurysms: Similarities, Differences, and Need for a New Class of Computational ModelsAnnual Review of Biomedical Engineering, 2008
- Constitutive Framework for Biodegradable Polymers with Applications to Biodegradable StentsASAIO Journal, 2008
- A Biodegradable Slotted Tube Stent Based on Poly(l-lactide) and Poly(4-hydroxybutyrate) for Rapid Balloon-ExpansionAnnals of Biomedical Engineering, 2007
- A note on viscoelastic materials that can ageInternational Journal of Non-Linear Mechanics, 2004
- Effect of soft‐segment chemistry on polyurethane biostability during in vitro fatigue loadingJournal of Biomedical Materials Research Part A, 2004
- Effect of strain and strain rate on fatigue‐accelerated biodegradation of polyurethaneJournal of Biomedical Materials Research Part A, 2003
- The Stress Clock Function in ViscoelasticityJournal of Rheology, 1980