The study of flow diversion effects on aneurysm using multiple enterprise stents and two flow diverters
Authors:
Open Access
- 1 December 2012
- journal article
- research article
- Published by Georg Thieme Verlag KG in Asian Journal of Neurosurgery
- Vol. 7 (04) , 159-165
Abstract
Background: Computer-based simulation is necessary to clarify the hemodynamics in brain aneurysm. Specifically for endovascular treatments, the effects of indwelling intravascular devices on blood stream need to be considered. The most recent technology used for cerebral aneurysm treatment is related to the use of flow diverters to reduce the amount of flow entering the aneurysm. To verify the differences of flow reduction, we analyzed multiple Enterprise stents and two kinds of flow diverters. Materials and Methods: In this research, we virtually modeled three kinds of commercial intracranial stents (Enterprise, Silk, and Pipeline) and mounted to fit into the vessel wall, and deployed across the neck of an IC-ophthalmic artery aneurysm. Also, we compared the differences among multiple Enterprise stents and two flow diverters in a standalone mode. Results: From the numerical results, the values of wall shear stress and pressure are reduced in proportion to the size of mesh, especially in the inflow area. However, the reduced velocity within the aneurysm sac by the multiple stents is not as significant as the flow diverters. Conclusions: This is the first study analyzing the flow alterations among multiple Enterprise stents and flow diverters. The placement of small meshed stents dramatically reduced the aneurysmal fluid movement. However, compared to the flow diverters, we did not observe the reduction of flow velocity within the aneurysm by the multiple stents.Keywords
This publication has 16 references indexed in Scilit:
- Intracranial Stents Being Modeled as a Porous Medium: Flow Simulation in Stented Cerebral AneurysmsAnnals of Biomedical Engineering, 2010
- Numerical simulation of hemodynamics in stented internal carotid aneurysm based on patient-specific modelJournal of Biomechanics, 2010
- The Effect of Stent Porosity and Strut Shape on Saccular Aneurysm and its Numerical Analysis with Lattice Boltzmann MethodAnnals of Biomedical Engineering, 2010
- Treatment of Intracranial Aneurysms by Functional Reconstruction of the Parent Artery: The Budapest Experience with the Pipeline Embolization DeviceAmerican Journal of Neuroradiology, 2010
- Reconstruction of the right anterior circulation with the Pipeline embolization device to achieve treatment of a progressively symptomatic, large carotid aneurysmJournal of NeuroInterventional Surgery, 2009
- Comparison of Two Stents in Modifying Cerebral Aneurysm HemodynamicsAnnals of Biomedical Engineering, 2008
- A New Endoluminal, Flow-Disrupting Device for Treatment of Saccular AneurysmsStroke, 2007
- Double-stent method: therapeutic alternative for small wide-necked aneurysmsJournal of Neurosurgery, 2004
- Treatment of a Ruptured Dissecting Vertebral Artery Aneurysm with Double Stent Placement: Case Report2001
- Endovascular treatment of intracranial aneurysms with Guglielmi Detachable Coils: emphasis on new techniquesJournal of Clinical Neuroscience, 2000