Transcatheter valve in valve implantation for failed mitral and tricuspid bioprosthesis
- 28 April 2011
- journal article
- valvular and-structural-heart-diseases
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 78 (7) , 987-995
Abstract
Objective: We report our experience with the transapical transcatheter “Valve in valve” implantation (T‐VIV) in patients with a failed mitral or tricuspid bioprosthesis; we briefly review the pertinent literature, and discuss some technical aspects of this procedure. Background: Redo valve surgery for failure of a mitral or tricuspid bioprosthesis might become extremely challenging, both because of the patients' condition, which is frequently poor, and for the technical aspects of the operation itself, that can be very demanding. T‐VIV has been widely employed with good results for the treatment of aortic bioprosthesis failure, and could represent an attractive option in this setting. Methods: Four patients with multiple comorbidities (age: 63‐83 years; logistic Euroscore: 37.2‐81.5) underwent T‐VIV at our institution for failure of a mitral [3] or tricuspid [1] bioprosthesis. A 26mm Sapien valve was used in all cases. All the mitral procedures were performed via a transapical approach. The tricuspid procedure was performed via a transjugular approach. Results: The first mitral procedure was complicated by the splaying of the xenograft stents and embolization of the valve. The procedure was converted to conventional surgery, and the patient died on postoperative day 1. In the subsequent procedures, the valve was positioned more atrially, and was fixed to the malfunctioning xenograft sewing ring. All subsequent procedures were successful, all patients were discharged home and were alive and well at follow‐up. Conclusions: The results of T‐VIV procedure in the mitral position have been suboptimal, and four of the sixteen patients reported to date died. However, all patients were extremely diseased, and some of the reported failures were related to amendable technical factors relative to the surgical access or to the valve deployment technique. With increasing experience, this procedure might become indicated as an alternative to conventional surgery in selected patients, encouraging increased use of bioprosthesis, and marking a pivotal change in the management of valvular disease.Keywords
This publication has 17 references indexed in Scilit:
- Transcatheter transapical mitral valve-in-valve implantations for a failed bioprosthesis: A case seriesThe Journal of Thoracic and Cardiovascular Surgery, 2011
- Percutaneous Tricuspid Valve Replacement for a Stenosed BioprosthesisCirculation: Cardiovascular Interventions, 2010
- Trans-apical aortic valve implantation: univariate and multivariate analyses of the early results from the SOURCE registry☆☆☆European Journal of Cardio-Thoracic Surgery, 2010
- Transapical Off-Pump Valve-in-Valve Implantation in Patients With Degenerated Aortic XenograftsThe Annals of Thoracic Surgery, 2010
- Transcatheter Valve-in-Valve Implantation for Failed Bioprosthetic Heart ValvesCirculation, 2010
- Transcatheter aortic valve replacementCatheterization and Cardiovascular Interventions, 2010
- Transapical aortic valve implantation after previous aortic valve replacementThe Thoracic and Cardiovascular Surgeon, 2010
- Transcatheter valve implantation for patients with aortic stenosis: a position statement from the European Association of Cardio-Thoracic Surgery (EACTS) and the European Society of Cardiology (ESC), in collaboration with the European Association of Percutaneous Cardiovascular Interventions (EAPCI)European Journal of Cardio-Thoracic Surgery, 2008
- Minimally invasive off-pump valve-in-a-valve implantation: the atrial transcatheter approach for re-operative mitral valve replacementEuropean Heart Journal, 2008
- Reoperation for Bioprosthetic Mitral Structural Failure: Risk AssessmentCirculation, 2003