Lesson of the month: extrinsic allergic (bronchiolo)alveolitis and metal working fluids

Authors:

Abstract
One of us was asked to consider a diagnosis of occupational asthma for a man who had worked for 20 years as a metal turner in a large, modern factory producing specialised machine parts. He described a 2 year history of severe breathlessness that improved when he was not at work. His spirometry was restrictive with a FEV1 of 1.35 L (40% predicted) and FVC of 1.8 L (45% predicted), a ratio of 75%. Other lung function measurements indicated gas trapping; his TLC was 5.01 L (79% predicted) and RV/TLC 170% predicted. A high resolution CT scan of his lungs revealed a widespread ‘mosaic’ pattern of attenuation indicative of small airflow obstruction. We made a diagnosis of occupational extrinsic allergic bronchioloalveolitis and recommended that he change his work. After 12 months working elsewhere in the same company, away from the machine shop, his dyspnoea was greatly improved but had not disappeared; his FVC had increased to 2.41 L, his FEV1 to 1.45 L and his TLC to 5.36 L.