A Rapid, Simple, and Low-Cost CD4 Cell Count Sensor Based on Blocking Immunochromatographic Strip System
Authors:
- Wei XiaoWXWei Xiao
- Meng XiaoMXMeng Xiao
- Shuange YaoSYShuange Yao
- Haicong ShenHSHaicong Shen
- Qiangqiang FuQFQiangqiang Fu
- Yong TangYTYong Tang
- 13 May 2019
- journal article
- research article
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 4 (6) , 1508-1514
Abstract
The counting of CD4+ T lymphocytes (CD4 cells) is a critical test for evaluating the immune function of HIV-infected peoples and tumor patients. A rapid, simple, accurate and low-cost CD4 cell counting method as a diagnostic tool is increasingly required in clinic. We designed and developed a novel fluorescent immunochromatographic strips (ICS) system based on blocking principle for counting CD4 cells. The strategy of this system is to count CD4 cells indirectly, by measuring the free CD4 antibodies that were not bound by CD4 cells. The fluorescent antibodies bound to CD4 cells were blocked at the filter pads, resulting in a de-crease in fluorescence of free CD4 antibodies measured. The number of CD4 cells was inversely related to the fluorescence inten-sity. The CD4 count-ICSs exhibited a quasilinear response (R2=0.96) to logarithmic CD4 cell concentrations in PBMC samples in the range of 50 to 1000 cells/μL. In addition, the CD4 count-ICSs reliably quantified CD4 cells in whole blood samples, where the assay exhibited a linear correlation (R2=0.976) readout for CD4 cell concentrations ranging from 100 to 800 cells/μL. To validate the clinical applicability of this method, 54 blood samples were measured, the detection results showed a high correlation (R2> 0.97) with the flow cytometry (FCM) analysis. The fluorescent ICSs can be used to count CD4 cells in blood samples, which have a high coincidence rate with FCM analysis, therefore, the CD4 count ICS system is an excellent candidate method for CD4 cell counting in resource-limited settings.Keywords
Funding Information
- Ministry of Science and Technology of the People's Republic of China (2016YFD0500600)
- Guangdong Province (2017Z0005)
This publication has 28 references indexed in Scilit:
- CD4 counting technologies for HIV therapy monitoring in resource-poor settings – state-of-the-art and emerging microtechnologiesLab on a Chip, 2013
- Lateral Flow Assay with Near-Infrared Dye for Multiplex DetectionClinical Chemistry, 2013
- Expanding roles for CD4+ T cells in immunity to virusesNature Reviews Immunology, 2012
- Emerging technologies for point-of-care CD4 T-lymphocyte countingTrends in Biotechnology, 2012
- Enumeration of CD4+ T-Cells Using a Portable Microchip Count Platform in Tanzanian HIV-Infected PatientsPLOS ONE, 2011
- A dual gold nanoparticle conjugate-based lateral flow assay (LFA) method for the analysis of troponin IBiosensors and Bioelectronics, 2010
- The ELISA, Enzyme-Linked Immunosorbent AssayClinical Chemistry, 2010
- Factors associated with CD4 lymphocyte counts in HIV-negative Senegalese individualsClinical and Experimental Immunology, 2008
- Point of Care TestingClinics In Laboratory Medicine, 2007
- Reference Values of CD4 T Lymphocytes in Human Immunodeficiency Virus-Negative Adult NigeriansClinical and Vaccine Immunology, 2005