Development of a sensitive monoclonal antibody-based ELISA for the determination of a β-adrenergic agonist brombuterol in swine meat, liver and feed samples
- 18 August 2016
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in Analytical Methods
- Vol. 8 (38) , 6941-6948
Abstract
A sensitive enzyme-linked immunosorbent assay (ELISA) based on a newly prepared monoclonal antibody (mAb) for the determination of a β-adrenergic agonist brombuterol in swine meat, liver and feed samples was developed. The immunogen and coating antigen were synthesized by directly linking brombuterol to carrier proteins using the diazobenzidine method. Mice immunized with the brombuterol–bovine serum albumin (BSA) conjugate were utilized for mAb generation whereas brombuterol–ovalbumin (OVA) was used as the coating antigen for the development of ELISA. Two hybridoma clones (13D12C1 and 4D11C1) specifically secreting antibodies against brombuterol were successfully isolated. Under optimal conditions, the IC50 and LOD values of the ELISA for brombuterol based on the mAb secreted by the 13D12C1 clone were found to be 0.56 ng mL−1 and 0.047 ng mL−1, respectively. The ELISA displayed no cross-reactivity with structurally related β-agonists (ractopamine, salbutamol, phenylethanolamine A, phenylephrine and isoproterenol) and five other veterinary drugs, but showed 52.8% cross-reactivity with clenbuterol. Swine meat, liver and feed samples were spiked with different content of brombuterol and detected by ELISA. The recovery rates and the coefficients of variation of the intra-assay and inter-assay were found to be in the range of 87.3–107.5% and 3.5–11.6% (n = 3), and 85.7–116.0% and 4.1–12.7% (n = 3), respectively. Spiked samples were analyzed by ELISA and HPLC simultaneously. A good correlation between the two methods was obtained. The results demonstrated that the proposed ELISA was a feasible quantitative/screening method for brombuterol analysis in swine meat, liver and feed samples with the properties of high sensitivity, high sample throughput and low cost.Keywords
Funding Information
- National Natural Science Foundation of China (21075087, 21175097)
This publication has 20 references indexed in Scilit:
- Highly sensitive multianalyte immunochromatographic test strip for rapid chemiluminescent detection of ractopamine and salbutamolAnalytica Chimica Acta, 2014
- Simultaneous Identification and Quantification of 20 β-Receptor Agonists in Feed Using Gas Chromatography-Tandem Mass SpectrometryPLOS ONE, 2013
- Surface plasmon resonance additivity of gold nanoparticles for colorimetric identification of cysteine and homocysteine in biological fluidsTalanta, 2013
- Overcoming matrix effects in electrospray: Quantitation of β-agonists in complex matrices by isotope dilution liquid chromatography–mass spectrometry using singly 13C-labeled analoguesJournal of Chromatography A, 2013
- Effect of ractopamine hydrochloride (Optaflexx) dose on live animal performance, carcass characteristics and tenderness in early weaned beef steersMeat Science, 2012
- Development an UHPLC-MS/MS Method for Detection of β-Agonist Residues in MilkFood Analytical Methods, 2011
- Food poisoning by clenbuterol in PortugalFood Additives & Contaminants, 2005
- Clinical and pharmacological profile in a clenbuterol epidemic poisoning of contaminated beef meat in ItalyToxicology Letters, 2000
- Effects of ractopamine at different dietary protein levels on growth performance and carcass characteristics in finishing pigsAnimal Feed Science and Technology, 1999
- Food poisoning related to consumption of illicit β-agonist in liverThe Lancet, 1990