Abstract
A spaceflight gamma-ray spectrometer, equipped with a high-purity germanium (HPGe) detector and a miniature rotary cryocooler with integral control electronics has been delivered to Japan’s Martian Moons eXploration (MMX) spacecraft. Operating a high-resolution germanium detector alongside a mechanical cryocooler presents significant challenges, particularly due to mechanical vibrations and electrical interference. To mitigate these effects, microphonic noise induced by cryocooler vibrations is reduced by appending double differentiation to a conventional trapezoidal pulse-shaping algorithm. This modification significantly increases the frequency roll-off below 10 kHz. Additionally, the shaping time is tuned to position a series of notch filters—introduced as a byproduct of digital delay line differentiation—beginning at the motor controller’s pulse-width-modulation (PWM) carrier frequency. This approach suppresses the fundamental switching frequency and its harmonics, effectively mitigating electromagnetic interference from the cryocooler controller located near the detector and its sensitive front-end preamplifier. Finally, the cryocooler’s rotational speed is dithered to distribute resonance effects observed at specific drive frequencies. Using these techniques, the MEGANE (Mars-moon Exploration with GAmma rays and NEutrons) instrument achieves an end-to-end energy resolution of 2.36 keV full width at half maximum (FWHM) at 1332 keV.
Funding Information
  • MEGANE project through the National Aeronautics and Space Administration (NASA) Discovery Program under Contract NNN06AA01C and in part by the Johns Hopkins University Applied Physics Laboratory.