A comparison of whole blood neutrophil chemiluminescence measured with cuvette and microtitre plate luminometers
- 11 January 2002
- journal article
- research article
- Published by Wiley in Luminescence
- Vol. 17 (1) , 1-4
Abstract
Results obtained by measuring human whole blood neutrophil chemiluminescence (CL) using the BioOrbit 1251 cuvette luminometer and the Immunotech LM‐01T microtitre plate luminometer are compared in this study. Opsonized zymosan, phorbol myristate acetate, N‐formyl–Met–Leu–Phe and calcium ionophore A23187 were used as activators. The CL response of neutrophils to their stimulation with the individual types of activators tested was fully detectable using either type of the luminometers. The kinetic curves of CL activity obtained from both the cuvette and the microtitre plate luminometers had similar characteristics. The only insignificant difference observed when comparing the kinetic curves was in the rates of the CL reactions. The peak CL response of activated neutrophils was reached faster when using the luminometer BioOrbit 1251 than with the luminometer Immunotech LM‐01T. A likely reason for this difference is the mode of transporting samples during the measurement, inducing different degrees of agitation. However, although this fact needs to be considered when interpreting results, both types of luminometer can be fully utilized in both research and clinical laboratories. Copyright © 2002 John Wiley & Sons, Ltd.Keywords
This publication has 14 references indexed in Scilit:
- Platelet-dependent modulation of polymorphonuclear leukocyte chemiluminescencePlatelets, 2000
- Measurement of whole blood phagocyte chemiluminescence in the Wistar ratJournal of Bioluminescence and Chemiluminescence, 1997
- Optimization of a phagocyte microplate chemiluminescent assayJournal of Bioluminescence and Chemiluminescence, 1995
- Biochemistry and Physiology of the Neutrophil1994
- Photon emission of phagocytes in relation to stress and diseaseCellular and Molecular Life Sciences, 1992
- The Effect of Various Cell Separation Procedures on Assays of Neutrophil Function: A Critical AppraisalAmerican Journal of Clinical Pathology, 1990
- Polymorphonuclear chemiluminescence: Some clinical applicationsJournal of Bioluminescence and Chemiluminescence, 1989
- Use of a microtitre plate chemiluminescence reader to study surface phagocytosis by human monocytesJournal of Bioluminescence and Chemiluminescence, 1989
- Measurement of phagocyte chemiluminescence using a microtitre plate luminometerJournal of Bioluminescence and Chemiluminescence, 1989
- Evidence for the generation of an electronic excitation state(s) in human polymorphonuclear leukocytes and its participation in bactericidal activityBiochemical and Biophysical Research Communications, 1972