Development and validation of a lipase nasogastric tube position test
Authors:
Open Access
- 1 March 2016
- journal article
- Published by BMJ in BMJ Open Gastroenterology
- Vol. 3 (1) , e000064
Abstract
Background: Nasogastric tube position should be checked every day by either aspirate pH or chest radiography to prevent fatal misplaced feeding into the lungs. Many patients do not have acidic gastric aspirates and require daily chest radiographs. We developed and validated a lipase test that was compatible with non-acidic gastric aspirates. Methods: We conducted evaluations of diagnostic test accuracy at a teaching hospital in development and validation stages. Development: We collected gastric and lung aspirates from 34 consecutive patients. We measured pH and human gastric lipase activity in the laboratory. These data helped us develop the lipase test. Ingenza Ltd (Roslin, Scotland) created tributyrin-coated pH test paper, which human gastric lipase converted into butyric acid, thus correcting false negatives. Validation: We tested nasogastric feeding tube aspirates from 36 consecutive patients with pH and lipase tests, using chest radiography or trial by use as the reference standard. Results: Development: We demonstrated human gastric lipase activity in the non-acidic stomach aspirates. Validation: The accuracy of the lipase test (sensitivity 97.2%, specificity 100%) was significantly better than pH (sensitivity 65.7%, specificity 100%, p<0.05). Conclusions: When nasogastric tube stomach aspirates were not acidic and pH was falsely negative, the lipase test showed a true positive and was significantly more accurate.Keywords
This publication has 18 references indexed in Scilit:
- QUADAS-2: A Revised Tool for the Quality Assessment of Diagnostic Accuracy StudiesAnnals of Internal Medicine, 2011
- A Team-Based Protocol and Electromagnetic Technology Eliminate Feeding Tube Placement ComplicationsAnnals of Surgery, 2011
- The development of a quality appraisal tool for studies of diagnostic reliability (QAREL)Journal of Clinical Epidemiology, 2010
- Confirmation of nasogastric tube position by pH testingJournal of Human Nutrition and Dietetics, 2005
- NHS safety agency issues guidance on nasogastric tubesBMJ, 2005
- ROC Curves in Clinical Chemistry: Uses, Misuses, and Possible SolutionsClinical Chemistry, 2004
- Sample Size Estimation: How Many Individuals Should Be Studied?Radiology, 2003
- Towards Complete and Accurate Reporting of Studies of Diagnostic Accuracy: The STARD InitiativeClinical Chemistry, 2003
- pH and Concentrations of Pepsin and Trypsin in Feeding Tube Aspirates as Predictors of Tube PlacementJournal of Parenteral and Enteral Nutrition, 1997
- Comparing the sensitivities and specificities of two diagnostic procedures performed on the same group of patients.British Journal of Radiology, 1997