Parameters influencing the outcome after total disc replacement at the lumbosacral junction. Part 1: misalignment of the vertebrae adjacent to a total disc replacement affects the facet joint and facet capsule forces in a probabilistic finite element analysis
- 20 July 2013
- journal article
- research article
- Published by Springer Nature in European Spine Journal
- Vol. 22 (10) , 2271-2278
Abstract
Purpose After total disc replacement with a ball-and-socket joint, reduced range of motion and progression of facet joint degeneration at the index level have been described. The aim of the study was to test the hypothesis that misalignment of the vertebrae adjacent to the implant reduces range of motion and increases facet joint or capsule tensile forces. Methods A probabilistic finite element analysis was performed using a lumbosacral spine model with an artificial disc at level L5/S1. Misalignment of the L5 vertebra, the gap size of the facet joints, the transection of the posterior longitudinal ligament, and the spinal shape were varied. The model was loaded with pure moments. Results Misalignment of the L5 vertebra reduced the range of motion up to 2°. A 2-mm displacement of the L5 vertebra in the anterior direction already led to facet joint forces of approximately 240 N. Extension, lateral bending, and axial rotation caused maximum facet joint forces between 280 and 380 N, while flexion caused maximum forces of approximately 200 N. A 2-mm displacement in the posterior direction led to capsule forces of approximately 80 N. Additional moments increased the maximum facet capsule forces to values between 120 and 230 N. Conclusions Misalignment of the vertebrae adjacent to an artificial disc strongly increases facet joint or capsule forces. It might, therefore, be an important reason for unsatisfactory clinical results. In an associated clinical study (Part 2), these findings are validated.Keywords
This publication has 28 references indexed in Scilit:
- Optimised in vitro applicable loads for the simulation of lateral bending in the lumbar spineMedical Engineering & Physics, 2012
- Effect of an artificial disc on lumbar spine biomechanics: a probabilistic finite element studyEuropean Spine Journal, 2008
- Degenerative Changes of Discs and Facet Joints in Lumbar Total Disc Replacement Using ProDisc IISpine, 2008
- CHARITÉ Versus ProDiscSpine, 2007
- Comparison of the effects of bilateral posterior dynamic and rigid fixation devices on the loads in the lumbar spine: a finite element analysisEuropean Spine Journal, 2007
- Analysis of the influence of disc degeneration on the mechanical behaviour of a lumbar motion segment using the finite element methodJournal of Biomechanics, 2006
- Spinal loads after osteoporotic vertebral fractures treated by vertebroplasty or kyphoplastyEuropean Spine Journal, 2005
- Role of Ligaments and Facets in Lumbar Spinal StabilitySpine, 1995
- Articular Facets of the Human Spine Quantitative Three-Dimensional AnatomySpine, 1993
- Mechanical Response of a Lumbar Motion Segment in Axial Torque Alone and Combined with CompressionSpine, 1986