Effect of compliant flooring on impact force during falls on the hip
Open Access
- 16 May 2006
- journal article
- research article
- Published by Wiley in Journal of Orthopaedic Research
- Vol. 24 (7) , 1405-1411
Abstract
Compliant flooring represents a promising but understudied strategy for reducing impact force and hip fracture risk due to falls in high-risk environments such as nursing homes, hospitals, gymnasiums, and senior centers. We conducted “pelvis release experiments” with young women (n = 15) to determine whether floor stiffness influences peak hip impact force during safe, low-height falls. During the trials, we used a pelvic sling and electromagnet to lift and instantly release the participant from a height of 5 cm above a force plate, which measured the force applied to the hip region during impact. Trials were conducted for rigid floor conditions and with layers of ethylene vinyl acetate foam rubber overlying the floor that we regarded as firm (1.5-cm thick; stiffness = 263 kN/m), semifirm (4.5-cm thick; stiffness = 95 kN/m), semisoft (7.5-cm thick; stiffness = 67 kN/m), and soft (10.5-cm thick; stiffness = 59 kN/m). When compared to the rigid condition, peak hip impact force averaged 8% lower in the firm condition and 15% lower in the semifirm condition. Peak forces were not significantly different between the semifirm, semisoft, and soft floor conditions, indicating that a 4.5 cm-thick foam mat provides nearly the same force attenuation as a 10.5 cm-thick mat. These results support the need for laboratory experiments to measure the effect of floor stiffness on postural stability and for clinical trials to determine the effect of compliant flooring on hip fracture incidence in high-risk environments. © 2006 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 24:1405–1411, 2006Keywords
This publication has 21 references indexed in Scilit:
- Epidemiology and outcomes of osteoporotic fracturesThe Lancet, 2002
- The Penn State Safety Floor: Part II—Reduction of Fall-Related Peak Impact Forces on the FemurJournal of Biomechanical Engineering, 1998
- Surface stiffness affects impact force during a fall on the outstretched handJournal of Orthopaedic Research, 1998
- Etiology and prevention of age-related hip fracturesBone, 1996
- Energy-Shunting Hip Padding System Attenuates Femoral Impact Force in a Simulated FallJournal of Biomechanical Engineering, 1995
- Energy-shunting external hip protector attenuates the peak femoral impact force below the theoretical fracture threshold: An in vitro biomechanical study under falling conditions of thel elderlyJournal of Bone and Mineral Research, 1995
- Effects of loading rate on strength of the proximal femurCalcified Tissue International, 1994
- Prediction of Femoral Impact Forces in Falls on the HipJournal of Biomechanical Engineering, 1991
- Risk Factors for Falls as a Cause of Hip Fracture in WomenThe New England journal of medicine, 1991
- Impact attenuation of floor coverings in simulated falling accidentsApplied Ergonomics, 1990