Abstract
Coagulopathy is common during left ventricular assist device (LVAD) implantation, treatment of which can be challenging given the often‐limited ability for the right ventricle to accommodate volume transfusion after device initiation with 20% to 40% of patients developing right ventricular failure (RVF). Transfusion of plasma late on cardiopulmonary bypass (CPB) combined with ultrafiltration may replace clotting factors while reducing volume administration. We compared outcomes in patients undergoing LVAD implantation receiving plasma on CPB and ultrafiltration with traditional transfusion practices. Co‐primary outcomes needed for blood product transfusion in the first 6 and 24 hours after CPB. Secondary outcomes included metrics of morbidity and mortality. 396 patients were analyzed (59 plasma on CPB). Patients receiving plasma on CPB had a greater volume of blood products transfused (3764 vs. 2741 mL first 6 hours; 6059 vs. 4305 mL first 24 hours) in unadjusted analysis. In adjusted analysis, plasma transfusion on CPB with ultrafiltration had no significant effect on the primary outcomes of blood products given in the first 6 hours (estimated effect size 982 [−428, 2392] mL, P = .17) and 24 hours (estimated effect size 1076 [−904, 3057] mL, P = .29). Patients receiving plasma on CPB were more likely on either vasopressors or inotropes at 24 hours after ICU admission (P = .01), however, indices of coagulopathy and RVF were similar between groups. While prospective studies would be necessary to definitively evaluate the clinical utility of this strategy, no signal for benefit was observed suggesting plasma should not be used for this purpose.Keywords
This publication has 21 references indexed in Scilit:
- Right-ventricular failure following left ventricle assist device implantationCurrent Opinion in Cardiology, 2013
- Right ventricular failure after LVAD implantation: Prevention and treatmentBest Practice & Research Clinical Anaesthesiology, 2012
- Longitudinal Shortening Accounts for the Majority of Right Ventricular Contraction and Improves After Pulmonary Vasodilator Therapy in Normal Subjects and Patients With Pulmonary Arterial HypertensionChest, 2011
- Bleeding Complications and Blood Product Utilization With Left Ventricular Assist Device ImplantationThe Annals of Thoracic Surgery, 2011
- Management of Right Ventricular Failure in the Era of Ventricular Assist Device TherapyCurrent Heart Failure Reports, 2011
- Right ventricular failure in patients with the HeartMate II continuous-flow left ventricular assist device: Incidence, risk factors, and effect on outcomesThe Journal of Thoracic and Cardiovascular Surgery, 2010
- Model for End-Stage Liver Disease Score Predicts Left Ventricular Assist Device Operative Transfusion Requirements, Morbidity, and MortalityCirculation, 2010
- Advanced Heart Failure Treated with Continuous-Flow Left Ventricular Assist DeviceThe New England journal of medicine, 2009
- Postoperative acute refractory right ventricular failure: incidence, pathogenesis, management and prognosisCardiovascular Surgery, 2000
- Septal Function During Left Ventricular UnloadingCirculation, 1997