Positive Airway Pressure Initiation: A Randomized Controlled Trial to Assess the Impact of Therapy Mode and Titration Process on Efficacy, Adherence, and Outcomes
Open Access
- 1 August 2011
- journal article
- research article
- Published by Oxford University Press (OUP) in SLEEP
- Vol. 34 (8) , 1083-1092
Abstract
(1) To determine the efficacy of automatically adjusted positive airway pressure (APAP) with a comfort feature (A-Flex) at reducing apneas and hypopneas in participants with moderate to severe OSA. (2) To determine the relative difference between A-Flex, continuous positive airway pressure (CPAP), and APAP-derived optimal pressure for CPAP (CPAPAPAP) on adherence to treatment. (3) To determine the relative difference between APAP with A-Flex, CPAP, and CPAPAPAP on long-term change in functional outcomes. Randomized, double-blinded, 3-arm, multicenter trial. University and Veterans Affairs medical centers. 168 participants were randomized, and 140 completed the 180-day study. (1) A-Flex; (2) CPAP; (3) APAP for 14 days and then switched to CPAP at a fixed pressure. Apnea-hypopnea indices, average and minimum oxygen saturation, time spent < 90% were significantly poorer for A-Flex vs. CPAP at the initiation of study treatment; with the exception of minimum oxygen saturation, these differences were absent at 180 days. A-Flex had lower average leak values at both 3 and 6 months. There were no significant differences between groups in major efficacy, adherence, and outcome (subjective sleepiness, objective vigilance, blood pressure, quality of life) measures. No differences between groups in attitudes toward use were observed at 3 or 6 months; participant ratings for CPAP were significantly higher than A-Flex on treatment satisfaction and benefit, but not different for sleep quality and mask comfort. We found that A-Flex shows equivalency, but non-superiority (except for average leak values), in efficacy, adherence, and functional outcomes compared to CPAP after either 3 or 6 months. Positive Pressure Treatment of Obstructive Sleep Apnea, http://www.clinicaltrials.gov, NCT00636181.Keywords
This publication has 36 references indexed in Scilit:
- Continuous positive airway pressure titration for obstructive sleep apnoea: automatic versus manual titrationThorax, 2010
- Auto bi-level with pressure relief during exhalation as a rescue therapy for optimally treated obstructive sleep apnoea patients with poor compliance to continuous positive airways pressure therapy—a pilot studySleep and Breathing, 2010
- Longitudinal comparison study of pressure relief (C-Flex™) vs. CPAP in OSA patientsSleep and Breathing, 2008
- Randomised trial of compliance with flexible (C-Flex) and standard continuous positive airway pressure for severe obstructive sleep apneaSleep and Breathing, 2008
- Exspiratorische Druckabsenkung (C-Flex) versus konstantem CPAP in der Therapie schlafbezogener obstruktiver AtemstörungenPneumologie, 2007
- Automatic Pressure Titration with APAP Is as Effective as Manual Titration with CPAP in Patients with Obstructive Sleep ApneaRespiration, 2007
- Treatment Adherence and Outcomes in Flexible vs Standard Continuous Positive Airway Pressure TherapyChest, 2005
- Randomized Short-term Trial of Two AutoCPAP Devices versus Fixed Continuous Positive Airway Pressure for the Treatment of Sleep ApneaAmerican Journal of Respiratory and Critical Care Medicine, 2003
- A Long-term Randomized, Cross-over Comparison of Auto-titrating and Standard Nasal Continuous Airway PressureSLEEP, 2000
- A New Method for Measuring Daytime Sleepiness: The Epworth Sleepiness ScaleSLEEP, 1991