The safety profile of Hemospan®: a new oxygen therapeutic designed using maleimide poly(ethylene) glycol conjugation to human hemoglobin
- 1 December 2007
- journal article
- Published by Wiley in Transfusion Alternatives in Transfusion Medicine
- Vol. 9 (4) , 213-225
Abstract
SUMMARY: Hemoglobin‐based oxygen carriers have been under development for several decades, but so far none has completed clinical trials due to safety issues, including fundamental concerns regarding hemoglobin‐induced vasoconstriction and oxidative reactions. The question becomes whether these attributes are inherent to the hemoglobin molecule itself, or if the molecule can be modified in such a way as to avoid untoward side effects. To this end, Sangart designed a new type of oxygen therapeutic, Hemospan®, based on site‐specific, maleimide poly(ethylene) glycol conjugation chemistry. The product, also referred to as MP4, is neither vasoconstrictive nor does it promote oxidation in vivo. The design principles were three‐fold: (i) increase hemoglobin molecular size to prolong intravascular retention; (ii) increase oxygen affinity to prevent premature unloading of oxygen in the arterioles, thus avoiding arteriolar vasoconstriction; and (iii) optimize colloidal osmotic pressure and viscosity to enhance blood flow. Preclinical studies with Hemospan in animal models of hemodilution and hemorrhage show maintenance of blood pressure and cardiac output, with improved oxygen delivery compared to early‐generation products of cross‐linked and polymerized hemoglobins. Four Phase I and II clinical trials have been completed, showing that Hemospan is generally well tolerated in humans, with additional evidence of efficacy through Hemospan's capacity to impart hemodynamic stability in surgical patients. Two multi‐center Phase III trials of Hemospan in orthopedic surgery are now underway in Europe.Keywords
This publication has 58 references indexed in Scilit:
- A quantitative framework for the design of acellular hemoglobins as blood substitutes: Implications of dynamic flow conditionsBiophysical Chemistry, 2007
- Dissociation of local nitric oxide concentration and vasoconstriction in the presence of cell-free hemoglobin oxygen carriersBlood, 2006
- Oxidation and haem loss kinetics of poly(ethylene glycol)-conjugated haemoglobin (MP4): dissociation between in vitro and in vivo oxidation ratesBiochemical Journal, 2006
- Ascorbate removes key precursors to oxidative damage by cell-free haemoglobin in vitro and in vivoBiochemical Journal, 2006
- 1.25 Å Resolution Crystal Structures of Human Haemoglobin in the Oxy, Deoxy and Carbonmonoxy FormsJournal of Molecular Biology, 2006
- Carbon Monoxide: Innovative Anti-inflammatory Properties of an Age-Old Gas MoleculeAntioxidants & Redox Signaling, 2002
- alphaalpha-Crosslinked Hemoglobin: Was Failure Predicted by Preclinical Testing?Vox Sanguinis, 2000
- Microvascular and tissue oxygen distributionCardiovascular Research, 1996
- The Physiological and Histopathological Response of Dogs to Exchange Transfusion with Polyethylene Glycol-Modified Bovine Hemoglobin (PEG-Hb)Artificial Cells, Blood Substitutes, and Biotechnology, 1996
- Proton NMR study of dynamics and thermodynamics of heme rotational disorder in native and reconstituted hemoglobin ABiochemistry, 1986