A comparison of the MARA and the AdvanSync functional appliances in the treatment of Class II malocclusion
- 1 September 2012
- journal article
- research article
- Published by The Angle Orthodontist (EH Angle Education & Research Foundation) in The Angle Orthodontist
- Vol. 82 (5) , 907-914
Abstract
Objectives: To determine the skeletal and dentoalveolar effects produced by the MARA and the AdvanSync functional appliances in the treatment of growing patients with Class II malocclusion. Materials and Methods: A retrospective study was conducted using lateral cephalograms of patients consecutively treated with MARA (n = 40) and AdvanSync (n = 30) during their skeletal growth spurt as evaluated by the improved cervical vertebral maturation method. A comparison was made with 24 untreated Class II control subjects obtained from the University of Michigan growth study and matched with the experimental groups for skeletal age, sex, and craniofacial morphology. Cephalograms were taken at three time points: (T1) pretreatment, (T2) postfunctional appliance treatment, and (T3) fixed orthodontic treatment completion. Treatment changes were evaluated between the time points using 35 variables. Data were analyzed using one-way analysis of variance and Scheffe's post hoc test. Results: At the postfunctional appliances' phase (T2–T1), both appliances showed significant increases in total mandibular length, ramus height, and anterior/posterior facial height. The AdvanSync resulted in significant restriction of maxillary growth, 1° more than MARA. This effect continued during the fixed orthodontic treatment stage (T3–T2). The net changes (T3–T1) revealed significant mandibular growth enhancement with MARA (+2.7mm) and significant headgear effect with AdvanSync. Both appliances caused 5° flaring in mandibular incisors as well as significant decreases in overjet and overbite. The treatment time for AdvanSync was 1 year less than MARA. Conclusion: The MARA and the AdvanSync resulted in normalization of the Class II malocclusion. The AdvanSync showed more headgear effect but less mandibular length enhancement than MARA did. Both appliances showed similar dentoalveolar changes.Keywords
This publication has 18 references indexed in Scilit:
- Treatment and posttreatment outcomes induced by the Mandibular Advancement Repositioning Appliance; A controlled clinical studyThe Angle Orthodontist, 2011
- Modified Camouflage Therapy in an Adult Class I Patient with TMJ Complaints. A Case ReportJournal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie, 2010
- Long-Term Dentoskeletal Changes with the Bionator, Herbst, Twin Block, and MARA Functional AppliancesThe Angle Orthodontist, 2010
- Effect of the MARA Appliance on the Position of the Lower Anteriors in Children, Adolescents and Adults with Class II MalocclusionJournal of Orofacial Orthopedics / Fortschritte der Kieferorthopädie, 2007
- The Cervical Vertebral Maturation (CVM) Method for the Assessment of Optimal Treatment Timing in Dentofacial OrthopedicsSeminars in Orthodontics, 2005
- Treatment effects of the mandibular anterior repositioning appliance on patients with Class II malocclusionAmerican Journal of Orthodontics and Dentofacial Orthopedics, 2003
- Stepwise advancement using fixed functional appliances: Experimental perspectiveSeminars in Orthodontics, 2003
- A method of cephalometric evaluationAmerican Journal of Orthodontics, 1984
- The “Wits” appraisal of jaw disharmonyAmerican Journal of Orthodontics, 1975
- Cephalometrics for you and meAmerican Journal of Orthodontics, 1953