13C Breath Tests Are Feasible in Patients With Extracorporeal Membrane Oxygenation Devices
- 3 November 2015
- journal article
- Published by Wiley in Artificial Organs
- Vol. 40 (7) , 692-698
Abstract
Temporary extracorporeal membrane oxygenation ( ECMO ) has been established as an essential part of therapy in patients with pulmonary or cardiac failure. As physiological gaseous exchange is artificially altered in this patient group, it is debatable whether a 13 C ‐breath test can be carried out. In this proof of technical feasibility report, we assess the viability of the 13 C ‐breath test LiMAx (maximum liver function capacity) in patients on ECMO therapy. All breath probes for the test device were obtained directly via the membrane oxygenator. Data of four patients receiving liver function assessment with the 13 C ‐breath test LiMAx while having ECMO therapy were analyzed. All results were compared with validated scenarios of the testing procedures. The LiMAx test could successfully be carried out in every case without changing ECMO settings. Clinical course of the patients ranging from multiorgan failure to no sign of liver insufficiency was in accordance with the results of the LiMAx liver function test. The 13 C ‐breath test is technically feasible in the context of ECMO . Further evaluation of 13 C ‐breath test in general would be worthwhile. The LiMAx test as a 13 C ‐breath test accessing liver function might be of particular predictive interest if patients with ECMO therapy develop multiorgan failure.Keywords
Funding Information
- University Hospital Charité, Berlin
This publication has 25 references indexed in Scilit:
- Extracorporeal Membrane Oxygenation in Cardiopulmonary Disease in AdultsJACC, 2014
- Referral to an Extracorporeal Membrane Oxygenation Center and Mortality Among Patients With Severe 2009 Influenza A(H1N1)JAMA, 2011
- The Italian ECMO network experience during the 2009 influenza A(H1N1) pandemic: preparation for severe respiratory emergency outbreaksIntensive Care Medicine, 2011
- How to define initial poor graft function after liver transplantation? - a new functional definition by the LiMAx testTransplant International, 2010
- The LiMAx test: a new liver function test for predicting postoperative outcome in liver surgeryHPB, 2010
- Early diagnosis of primary nonfunction and indication for reoperation after liver transplantationLiver Transplantation, 2010
- Efficacy and economic assessment of conventional ventilatory support versus extracorporeal membrane oxygenation for severe adult respiratory failure (CESAR): a multicentre randomised controlled trialThe Lancet, 2009
- Prediction of Postoperative Outcome After Hepatectomy With a New Bedside Test for Maximal Liver Function CapacityAnnals of Surgery, 2009
- Use of Extracorporeal Membrane Oxygenation as a Bridge to Primary Lung Transplant: 3 Consecutive, Successful Cases and a Review of the LiteratureThe Journal of Heart and Lung Transplantation, 2008
- Bridge to lung transplantation with the novel pumpless interventional lung assist device NovaLungThe Journal of Thoracic and Cardiovascular Surgery, 2006