Systematic review and meta-analysis of duplex ultrasonography, contrast-enhanced ultrasonography or computed tomography for surveillance after endovascular aneurysm repair
- 21 September 2012
- journal article
- review article
- Published by Oxford University Press (OUP) in British Journal of Surgery
- Vol. 99 (11) , 1514-1523
Abstract
Background: Previous analyses suggested that duplex ultrasonography (DUS) detected endoleaks after endovascular aneurysm repair (EVAR) with insufficient sensitivity; they did not specifically examine types 1 and 3 endoleak, which, if untreated, may lead to aneurysm-related death. In light of changes to clinical practice, the diagnostic accuracy of DUS and contrast-enhanced ultrasonography (CEUS) for types 1 and 3 endoleak required focused reappraisal. Methods: Studies comparing DUS or CEUS with computed tomography (CT) for endoleak detection were identified. CT was taken as the standard in bivariable meta-analysis. Results: Twenty-five studies (3975 paired scans) compared DUS with CT for all endoleaks. The pooled sensitivity was 0·74 (95 per cent confidence interval 0·62 to 0·83) and the pooled specificity was 0·94 (0·90 to 0·97). Thirteen studies (2650 paired scans) reported detection of types 1 and 3 endoleak by DUS; the pooled sensitivity of DUS was 0·83 (0·40 to 0·97) and the pooled specificity was 1·00 (0·97 to 1·00). Eleven studies (961 paired scans) compared CEUS with CT for all endoleaks. The pooled sensitivity of CEUS was 0·96 (0·85 to 0·99) and the pooled specificity was 0·85 (0·76 to 0·92). Eight studies (887 paired scans) reported detection of types 1 and 3 endoleak by CEUS. The pooled sensitivity of CEUS was 0·99 (0·25 to 1·00) and the pooled specificity was 1·00 (0·98 to 1·00). Conclusion: Both CEUS and DUS were specific for detection of types 1 and 3 endoleak. Estimates of their sensitivity were uncertain but there was no evidence of a clinically important difference. DUS detects types 1 and 3 endoleak with sufficient accuracy for surveillance after EVAR.Keywords
This publication has 66 references indexed in Scilit:
- Current Evidence Is Insufficient to Define an Optimal Threshold for Intervention in Isolated Type II Endoleak After Endovascular Aneurysm RepairJournal of Endovascular Therapy, 2012
- Surveillance Imaging Modality does not Affect Detection Rate of Asymptomatic Secondary Interventions following EVAREuropean Journal of Vascular and Endovascular Surgery, 2012
- Heterogeneity in Surveillance after Endovascular Aneurysm Repair in the UKEuropean Journal of Vascular and Endovascular Surgery, 2011
- Duplex ultrasound imaging alone is sufficient for midterm endovascular aneurysm repair surveillance: A cost analysis study and prospective comparison with computed tomography scanJournal of Vascular Surgery, 2009
- Endoleak after endovascular aneurysm repair: Duplex ultrasound imaging is better than computed tomography at determining the need for interventionJournal of Vascular Surgery, 2009
- Long-term surveillance with computed tomography after endovascular aneurysm repair may not be justifiedBritish Journal of Surgery, 2009
- Long-term outcome of endovascular abdominal aortic aneurysm repairBritish Journal of Surgery, 2009
- Contrast ultrasound imaging: the best method to detect type II endoleak during endovascular aneurysm repair follow-up☆Interactive CardioVascular and Thoracic Surgery, 2007
- Computed Tomography Versus Color Duplex Ultrasound for Surveillance of Abdominal Aortic Stent-GraftsJournal of Endovascular Therapy, 2005
- Quantifying heterogeneity in a meta‐analysisStatistics in Medicine, 2002