Background Fluid challenge test is a widely used method for the detection of fluid responsiveness in acute circulatory failure. However, detection of the patient's response to the fluid challenge requires monitoring of cardiac output which is not feasible in many settings. We investigated whether the changes in the pulse oximetry-derived peripheral perfusion index (PPI), as a non-invasive surrogate of cardiac output, can detect fluid responsiveness using the fluid challenge test or not. Methods We prospectively enrolled 58 patients with septic shock on norepinephrine infusion. Fluid challenge test, using 200 mL crystalloid solution, was performed in all study subjects. All patients received an additional 300 mL crystalloid infusion to confirm fluid responsiveness. Velocity time integral (VTI) (using transthoracic echocardiography), and PPI were measured at the baseline, after 200 mL fluid challenge, and after completion of 500 mL crystalloids. Fluid responsiveness was defined by 10% increase in the VTI after completion of the 500 mL. The predictive ability of ∆PPI [Calculated as (PPI after 200 mL − baseline PPI)/baseline PPI] to detect fluid responders was obtained using the receiver operating characteristic curve. Results Forty-two patients (74%) were fluid responders; in whom, the mean arterial pressure, the central venous pressure, the VTI, and the PPI increased after fluid administration compared to the baseline values. ∆PPI showed moderate ability to detect fluid responders [area under receiver operating characteristic curve (95% confidence interval) 0.82 (0.70–0.91), sensitivity 76%, specificity 80%, positive predictive value 92%, negative predictive value 54%, cutoff value ≥ 5%]. There was a significant correlation between ∆PPI and ∆VTI induced by the fluid challenge. Conclusion ∆PPI showed moderate ability to detect fluid responsiveness in patients with septic shock on norepinephrine infusion. Increased PPI after 200 mL crystalloid challenge can detect fluid responsiveness with a positive predictive value of 92%; however, failure of the PPI to increase does not exclude fluid responsiveness. Clinical trial identifier NCT03805321. Date of registration: 15 January 2019. Clinical trial registration URL: https://clinicaltrials.gov/ct2/show/NCT03805321?term=ahmed+hasanin&rank=9.Keywords
This publication has 25 references indexed in Scilit:
- Changes of central venous oxygen saturation define fluid responsiveness in patients with septic shock: A prospective observational studyJournal of Critical Care, 2017
- Evaluation of perfusion index as a tool for pain assessment in critically ill patientsJournal of Clinical Monitoring and Computing, 2016
- Fluid responsiveness in acute circulatory failureJournal of Intensive Care, 2015
- Response to Fluid Boluses in the Fluid and Catheter Treatment TrialChest, 2015
- A positive fluid balance is an independent prognostic factor in patients with sepsisCritical Care, 2015
- Tissue perfusion and oxygenation to monitor fluid responsiveness in critically ill, septic patients after initial resuscitation: a prospective observational studyJournal of Clinical Monitoring and Computing, 2015
- Evaluation of pulse pressure variation validity criteria in critically ill patients: a prospective observational multicentre point-prevalence study †British Journal of Anaesthesia, 2013
- Fluid challenge: tracking changes in cardiac output with blood pressure monitoring (invasive or non-invasive)Intensive Care Medicine, 2013
- An Increase in Aortic Blood Flow after an Infusion of 100 ml Colloid over 1 Minute Can Predict Fluid ResponsivenessAnesthesiology, 2011
- Use of a peripheral perfusion index derived from the pulse oximetry signal as a noninvasive indicator of perfusionCritical Care Medicine, 2002