Abstract
Periodic spirometry testing is performed in medical screening and surveillance programs for workers with various occupational exposures and for cigarette smokers. The recent American College of Occupational and Environmental Medicine (ACOEM) evidence-based statement, Spirometry in the Occupational Setting, comprehensively reviewed the issues involved in conducting and interpreting standardized spirometry tests in occupational medicine.1 However, interpreting change over time was only briefly discussed in that statement, and little other guidance on assessing longitudinal change in lung function is available for health professionals. As a result, many practitioners do not evaluate change in lung function over time, but instead repeatedly determine whether each year's test results fall within the normal range. Other practitioners evaluate change over time or “trending” but are unaware of the pitfalls that can distort their evaluations. Although health professionals must determine whether evaluating lung function change over time effectively screens for a specific outcome disease,2–4 the ACOEM Occupational and Environmental Lung Disorder Committee recognized the need to provide guidance in the selection and use of simple measures of change over time. The Committee developed this separate ACOEM position statement to: 1) explain the need for longitudinal analysis of pulmonary function when evaluating employee respiratory health; 2) describe the pitfalls to be avoided when collecting serial measurements for longitudinal analysis; and 3) recommend simple criteria to use for flagging abnormal change in pulmonary function over time. The statement's key points are summarized in Table 1. Real-life examples illustrate the pitfalls to be avoided and the application of longitudinal methods for evaluating pulmonary function. Spirometry is performed periodically in screening and surveillance programs for a variety of occupational exposures. Occupational Safety and Health Administration (OSHA) regulations require periodic spirometry testing for certain workers exposed to asbestos,5 coke oven emissions,6 cadmium,7 cotton dust,8 benzene,9 and formaldehyde.10 Many companies mandate medical surveillance with periodic spirometry testing for additional exposures as well as incorporating spirometry into their respirator medical clearance screening programs. In each case, health professionals must evaluate current and previous test results to determine whether an employee is at increased risk of impairment from further occupational exposure or if any limitations should be placed on the employee's activities or use of personal protective equipment. However, the details of the evaluation of current and previous results are usually not specified. The OSHA Cotton Dust Standard is only slightly more explicit than the other OSHA regulations listed here, stating that “a determination [shall be] made by the physician as to whether there has been a significant change [between the current examination results and those of previous examinations].”8 Traditionally, an individual's measured lung function has been compared with a “predicted” value, ie, the average expected for an asymptomatic nonsmoker of the subject's age, height, race/ethnicity, and sex. Many sources of predicted values have been derived from studies of asymptomatic nonsmoking populations, and some applications require the use of specific sets of prediction equations. Selection of reference values has been reviewed elsewhere.1,11–15 The comparison of observed with predicted values is usually summarized in a numeric index, the percent of predicted (% Pred). Lower limits of normal should be determined for the prediction equations in use, and the individual's measured results are then interpreted relative to the normal range as normal or abnormal and possibly impaired.

This publication has 21 references indexed in Scilit: