Method to Reduce Aerosolized Contaminant Concentration Exposure to Healthcare Workers During the COVID-19 Pandemic when Temporary Isolation Systems Are Required
Open Access
- 27 October 2020
- journal article
- research article
- Published by Western Journal of Emergency Medicine in Western Journal of Emergency Medicine
- Vol. 21 (6) , 93-98
Abstract
The COVID-19 pandemic has strained the healthcare system. It has led to the use of temporary isolation systems and less-then-optimum patient placement configurations because of inadequate number of isolation rooms, both of which can compromise provider safety. Three key elements require special attention to reduce the maximum and average aerosolized contaminant concentration exposure to a healthcare worker in any isolation system: flow rate; air changes per hour; and patient placement. This is important because concentration exposures of aerosolized contaminants to healthcare workers in hospitals using temporary isolation systems can reach levels 21-30 times greater than a properly engineered negative pressure isolation room. A working knowledge of these three elements can help create a safer environment for healthcare workers when isolation rooms are not available.Keywords
This publication has 4 references indexed in Scilit:
- Barrier Enclosure during Endotracheal IntubationNew England Journal of Medicine, 2020
- Movement of airborne contaminants in a hospital isolation roomJournal of The Royal Society Interface, 2009
- Control of airborne infectious diseases in ventilated spacesJournal of The Royal Society Interface, 2009
- Modeling Indoor Air Concentrations Near Emission Sources in Imperfectly Mixed RoomsJournal of the Air & Waste Management Association, 1996