Combined kinetics and iterative target transformation factor analysis for spectroscopic monitoring of reactions
Authors:
- 18 November 2005
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in The Analyst
- Vol. 131 (1) , 90-97
Abstract
Obtaining rate constants and concentration profiles from spectroscopy is important in reaction monitoring. In this paper, we combined kinetic equations and Iterative Target Transformation Factor Analysis (ITTFA) to resolve spectroscopic data acquired during the course of a reaction. This approach is based on the fact that ITTFA needs a first guess (test vectors) of the parameters that will be estimated (target vectors). Three methods are compared. In the first, originally proposed by Furusjö and Danielsson, kinetic modelling is only used to provide the initial test vectors for ITTFA. In the second the rate constant used to provide the test vectors is optimised until a best fit is reached. In the third, a guess of the rate constant is used to provide the test vectors to ITTFA. The outcome of ITTFA is then used to fit the kinetic model and obtain a new guess of the rate constant. With this constant new concentration profiles are generated and provided to the ITTFA algorithm as new test vectors, in an iterative manner, minimising the residuals of the predicted dataset, until convergence. The second and third methods are new implementations of ITTFA and are compared to the first, established, method. First order (both one and two step) and second order reactions were simulated and instrumental noise was introduced. An experimental second order reaction was also employed to test the methods.Keywords
This publication has 25 references indexed in Scilit:
- Comparison of PLS and kinetic models for a second-order reaction as monitored using ultraviolet visible and mid-infrared spectroscopyTalanta, 2006
- Monitoring of a second‐order reaction by electronic absorption spectroscopy using combined chemometric and kinetic modelsJournal of Chemometrics, 2003
- Application of a novel resolution approach combining soft- and hard-modelling features to investigate temperature-dependent kinetic processesAnalytica Chimica Acta, 2001
- Target transform fitting: a new method for the non‐linear fitting of multivariate data with separable parametersJournal of Chemometrics, 2001
- Multivariate curve resolution with alternating least squares optimisation: a soft-modelling approach to metal complexation studies by voltammetric techniquesTrAC Trends in Analytical Chemistry, 2000
- A method for the determination of reaction mechanisms and rate constants from two-way spectroscopic dataAnalytica Chimica Acta, 1998
- Evolving factor analysis applied to flow injection analysis dataJournal of Chemometrics, 1989
- Multicomponent self-modelling curve resolution in high-performance liquid chromatography by iterative target transformation analysisAnalytica Chimica Acta, 1985
- A priori estimates of the elution profiles of the pure components in overlapped liquid chromatography peaks using target factor analysisJournal of Chemical Information and Computer Sciences, 1984
- Theory of error for target factor analysis with applications to mass spectrometry and nuclear magnetic resonance spectrometryAnalytica Chimica Acta, 1978