CT Versus Sonography for Monitoring Radiofrequency Ablation in a Porcine Liver

Authors:

Abstract
OBJECTIVE. The objective of this study was to compare CT and sonography for monitoring radiofrequency (RF) lesions in porcine livers.SUBJECTS AND METHODS. RF lesions (n = 12) were created in three pig livers by applying 13 min of current to a multielectrode RF probe with a target temperature of 95°C. Helical unenhanced CT and corresponding axial sonography were performed before ablation, at 2 min, 8 min, and immediately after ablation. Contrast-enhanced CT was performed after ablation. CT scans and sonograms were evaluated by blinded observers for conspicuity of the RF lesion, edge detection (visibility of liver—lesion interface), and artifacts. Hounsfield units were recorded at every time interval, and radiologic—pathologic correlation for lesion size and configuration was performed.RESULTS. Mean size of RF lesions was 3.03 ± 0.9 cm. On CT, RF lesions had consistently lower attenuation values than surrounding liver (22.2 H lower than liver at 8 min, p < 0.0001). Echogenicity was variable with sonography ...

This publication has 19 references indexed in Scilit: