Utilization of mechanical quadrature in silicon MEMS vibratory gyroscope to increase and expand the long term in-run bias stability
Authors:
- 1 February 2014
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-4
Abstract
We report a new approach for improvement of the long term in-run bias stability of Coriolis vibratory gyroscopes. The approach is based on utilization of the mechanical quadrature error in gyroscopes to compensate for variation in system parameters. The proposed approach was validated by a silicon Quadruple Mass Gyroscope, with the natural frequency of 3 kHz, frequency mismatch of <;0.5 Hz, and isotropic quality factor of 950, packaged without getter. The algorithm is described and experimentally demonstrated in this paper, showing a bias stability of 0.1 deg/hr after 300 seconds, and importantly, retaining that value for over 3 hours of the integration time.Keywords
This publication has 5 references indexed in Scilit:
- High and Moderate-Level Vacuum Packaging of Vibratory MEMSInternational Symposium on Microelectronics, 2013
- Anti-phase mode isolation in tuning-fork MEMS using a lever coupling design2012
- Ultra-high Q silicon gyroscopes with interchangeable rate and whole angle modes of operation2010
- A Novel Capacitive Detection Scheme With Inherent Self-CalibrationJournal of Microelectromechanical Systems, 2007
- Capacitive detection in resonant MEMS with arbitrary amplitude of motionJournal of Micromechanics and Microengineering, 2007