A respiratory‐gated micro‐CT comparison of respiratory patterns in free‐breathing and mechanically ventilated rats
Open Access
- 23 January 2017
- journal article
- research article
- Published by Wiley in Physiological Reports
- Vol. 5 (2) , e13074
Abstract
In this study, we aim to quantify the differences in lung metrics measured in free‐breathing and mechanically ventilated rodents using respiratory‐gated micro‐computed tomography. Healthy male Sprague‐Dawley rats were anesthetized with ketamine/xylazine and scanned with a retrospective respiratory gating protocol on a GE Locus Ultra micro‐CT scanner. Each animal was scanned while free‐breathing, then intubated and mechanically ventilated (MV) and rescanned with a standard ventilation protocol (56 bpm, 8 mL/kg and PEEP of 5 cm H2O) and again with a ventilation protocol that approximates the free‐breathing parameters (88 bpm, 2.14 mL/kg and PEEP of 2.5 cm H2O). Images were reconstructed representing inspiration and end expiration with 0.15 mm voxel spacing. Image‐based measurements of the lung lengths, airway diameters, lung volume, and air content were compared and used to calculate the functional residual capacity (FRC) and tidal volume. Images acquired during MV appeared darker in the airspaces and the airways appeared larger. Image‐based measurements showed an increase in lung volume and air content during standard MV, for both respiratory phases, compared with matched MV and free‐breathing. Comparisons of the functional metrics showed an increase in FRC for mechanically ventilated rats, but only the standard MV exhibited a significantly higher tidal volume than free‐breathing or matched MV. Although standard mechanical ventilation protocols may be useful in promoting consistent respiratory patterns, the amount of air in the lungs is higher than in free‐breathing animals. Matching the respiratory patterns with the free‐breathing case allowed similar lung morphology and physiology measurements while reducing the variability in the measurements.Keywords
Funding Information
- Natural Sciences and Engineering Research Council of Canada
- University of British Columbia
This publication has 35 references indexed in Scilit:
- In Vivo Micro-CT Assessment of Airway Remodeling in a Flexible OVA-Sensitized Murine Model of AsthmaPLOS ONE, 2012
- Quantification of Lung Fibrosis and Emphysema in Mice Using Automated Micro-Computed TomographyPLOS ONE, 2012
- Lung tumour growth kinetics in SPC-c-Raf-1-BB transgenic mice assessed by longitudinal in-vivo micro-CT quantificationJournal of Experimental & Clinical Cancer Research, 2012
- Quantifying lung morphology with respiratory-gated micro-CT in a murine model of emphysemaPhysics in Medicine & Biology, 2009
- The effects of long-term conventional mechanical ventilation on the lungs of adult rats*Critical Care Medicine, 2008
- Optimization of a retrospective technique for respiratory-gated high speed micro-CT of free-breathing rodentsPhysics in Medicine & Biology, 2007
- In vivo characterization of lung morphology and function in anesthetized free-breathing mice using micro-computed tomographyJournal of Applied Physiology, 2007
- LUNG MECHANICS IN THE TIMP3 NULL MOUSE AND ITS RESPONSE TO MECHANICAL VENTILATIONExperimental Lung Research, 2007
- A NOVEL MODEL OF SELECTIVE LUNG VENTILATION TO INVESTIGATE THE LONG-TERM EFFECTS OF VENTILATION-INDUCED LUNG INJURYShock, 2006
- Improved method ofin vivorespiratory-gated micro-CT imagingPhysics in Medicine & Biology, 2004