Magnetically guided left ventricular lead implantation based on a virtual three-dimensional reconstructed image of the coronary sinus
Open Access
- 4 August 2008
- journal article
- clinical trial
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 10 (9) , 1042-1047
Abstract
Left ventricular (LV) lead implantation is feasible using remote magnetic navigation of a guidewire (Stereotaxis, St Louis, MO, USA). A novel software that performs a three-dimensional (3D) reconstruction of vessels based on two or more angiographic views has been developed recently (CardiOp-B system, Paeion Inc., Haifa, Israel). The objective of this paper is to evaluate: (i) the performance of the 3D reconstruction software which reproduce the anatomy of the coronary sinus (CS) and (ii) the efficacy of remotely navigating a magnetic guidewire within the CS based on this reconstruction. In patients undergoing cardiac resynchronization therapy implantation, a 3D reconstruction of the CS was performed using the CardiOp-B system. Accuracy of the reconstruction was evaluated by comparing with the CS angiogram. This reconstruction was imported into the Stereotaxis system. On the basis of the reconstruction, magnetic vectors were automatically selected to navigate within the CS and manually adjusted if required. Feasibility of deploying the guidewire and LV lead into the selected side branch (SB), fluoroscopy time (FT) required for cannulation of the target SB, and total FT were also evaluated. Sixteen patients were included. In one case, the software could not reconstruct the CS. The quality of the reconstruction was graded as good in 13 and poor in 2. In 10 cases, manual adjustments to the traced edges of the CS were required to perform the 3D reconstruction, and in 5, no adjustments were required. In 13 patients, the target SB was engaged on the basis of the automatically selected vectors. In two cases, manual modification of the vector was required. Mean total FT was 23 +/- 14 min and the FT required to cannulate the target SB was 1.7 +/- 1.3 min. A 3D reconstruction of the CS can be accurately performed using two angiographic views. This reconstruction allows precise magnetic navigation of a guidewire within the CS.Keywords
This publication has 12 references indexed in Scilit:
- First direct in vivo comparison of two commercially available three‐dimensional quantitative coronary angiography systemsCatheterization and Cardiovascular Interventions, 2007
- A grateful heartEP Europace, 2007
- Magnetic Navigation in Left-Sided AV Reentrant Tachycardias: Preliminary Results of a Retrograde ApproachJournal of Cardiovascular Electrophysiology, 2007
- Magnetic navigation system used successfully to cross a crushed stent in a bifurcation that failed with conventional wiresCatheterization and Cardiovascular Interventions, 2007
- Left ventricular lead implantation assisted by magnetic navigation in a patient with a persistent left superior vena cavaInternational Journal of Cardiology, 2007
- Initial Clinical Experience with Cardiac Resynchronization Therapy Utilizing a Magnetic Navigation SystemJournal of Cardiovascular Electrophysiology, 2007
- Magnetic navigation in AV nodal re-entrant tachycardia study: early results of ablation with one- and three-magnet cathetersEP Europace, 2006
- Left Ventricular Lead Placement Within a Coronary Sinus Side Branch Using Remote Magnetic Navigation of a Guidewire: A Feasibility StudyJournal of Cardiovascular Electrophysiology, 2005
- Three‐Dimensional Reconstruction of the Coronary Sinus Using Rotational AngiographyJournal of Cardiovascular Electrophysiology, 2005
- Robotically assisted left ventricular epicardial lead implantation for biventricular pacingJACC, 2003