Bone Marrow Abnormalities of Foot and Ankle: STIR versus T1-weighted Contrast-enhanced Fat-suppressed Spin-Echo MR Imaging
Authors:
- Marius R. SchmidMSMarius R. Schmid
- Juerg HodlerJHJuerg Hodler
- Patrick ViennePVPatrick Vienne
- Christoph A. BinkertCBChristoph A. Binkert
- Marco ZanettiMZMarco Zanetti
- 1 August 2002
- journal article
- research article
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 224 (2) , 463-469
Abstract
To compare short inversion time inversion-recovery (STIR) and T1-weighted contrast material-enhanced fat-suppressed spin-echo magnetic resonance (MR) sequences for depiction of bone marrow abnormalities of the foot and ankle. Fifty-one consecutive patients with bone marrow abnormalities depicted on turbo STIR images were examined with additional T1-weighted contrast-enhanced (0.1 mmol/kg gadopentetate dimeglumine) MR imaging with fat suppression. Volume and signal difference-to-noise ratio (SDNR) were measured. An additional qualitative analysis was performed by two experienced musculoskeletal radiologists to correlate the presence or absence of ill-defined edema-like zones, well-defined zones, and cystlike zones. Diagnoses determined with MR findings with each sequence were compared with the results of a review panel. Correlation coefficients (r(2)) and paired t tests were calculated for all measurements. Agreement percentages and kappa values were calculated for inter- and intraobserver reproducibility. Regarding volume of bone marrow abnormalities, a high correlation (r(2) = 0.98) of both sequences was found. SDNR was substantially higher on T1-weighted contrast-enhanced images than on STIR images (mean, 125.9 vs 95.4; P <.001). The qualitative analysis demonstrated identical imaging patterns with both sequences in 96% (79 of 82, kappa = 0.38) of ill-defined zones, in 88% (72 of 82, kappa = 0.76) of well-defined zones, and in 98% (80 of 82, kappa = 0.84) of cystlike zones. Interobserver reproducibility of the three imaging patterns was similar for both sequences. The kappa values for these three zones with STIR sequence were 0.55, 0.68, and 0.69, and those for the T1-weighted contrast-enhanced MR sequence were 0.49, 0.73, and 0.58, respectively. Diagnoses determined with MR findings were equal with both sequences in 94% (80 of 85) of involved bones. STIR images and T1-weighted contrast-enhanced fat-suppressed MR images demonstrate almost identical imaging patterns, and diagnoses determined with these findings show little difference.Keywords
This publication has 23 references indexed in Scilit:
- Bone Marrow Edema Pattern in Osteoarthritic Knees: Correlation between MR Imaging and Histologic FindingsRadiology, 2000
- Morton Neuroma: Effect of MR Imaging Findings on Diagnostic Thinking and Therapeutic DecisionsRadiology, 1999
- MR imaging of anterosuperior calcaneal process fractures.American Journal of Roentgenology, 1999
- MR imaging of musculoskeletal tumors and tumor mimickers with intravenous gadolinium: experience with 242 patientsSkeletal Radiology, 1997
- MR diagnosis of bone contusions of the knee: comparison of coronal T2-weighted fast spin-echo with fat saturation and fast spin-echo STIR images with conventional STIR images.American Journal of Roentgenology, 1996
- MR imaging of bone marrow edema pattern: transient osteoporosis, transient bone marrow edema syndrome, or osteonecrosis.RadioGraphics, 1993
- Bone marrow imaging using STIR at 0.5 and 1.5 TMagnetic Resonance Imaging, 1992
- Histologic and magnetic resonance imaging correlations in Kienböck's diseaseThe Journal of Hand Surgery, 1990
- Value of MR imaging in staging osteochondral lesions of the talus (osteochondritis dissecans): results in 14 patients.American Journal of Roentgenology, 1990
- Magnetic resonance imaging in the evaluation of suspected osteonecrosis of the kneeSkeletal Radiology, 1987