Abstract
Background: Currently available silicone and metallic stents for tracheal stenosis are associated with many problems. Granulation proliferation is one of the main complications. The present study aimed to evaluate the efficacy of paclitaxel drug-eluting tracheal stent in reducing granulation tissue formation in a canine model, as well as the pharmacokinetic features and safety profiles of the coated drug. Methods: Eight beagles were randomly divided into a control group (bare-metal stent group, n = 4) and an experimental group (paclitaxel-eluting stent group, n = 4). The observation period was 5 months. One beagle in both groups was sacrificed at the end of the 1st and 3rd months, respectively. The last two beagles in both groups were sacrificed at the end of 5th month. The proliferation of granulation tissue and changes in tracheal mucosa were compared between the two groups. Blood routine and liver and kidney function were monitored to evaluate the safety of the paclitaxel-eluting stent. The elution method and high-performance liquid chromatography were used to characterize the rate of in vivo release of paclitaxel from the stent. Results: Compared with the control group, the proliferation of granulation tissue in the experimental group was significantly reduced. The drug release of paclitaxel-eluting stent was the fastest in the 1st month after implantation (up to 70.9%). Then, the release slowed down gradually. By the 5th month, the release reached up to 98.5%. During the observation period, a high concentration of the drug in the trachea (in the stented and adjacent unstented areas) and lung tissue was not noted, and the blood test showed no side effect. Conclusions: The paclitaxel-eluting stent could safely reduce the granulation tissue formation after stent implantation in vivo, suggesting that the paclitaxel-eluting tracheal stent might be considered for potential use in humans in the future.Keywords
This publication has 26 references indexed in Scilit:
- A novel bioabsorbable drug‐eluting tracheal stentThe Laryngoscope, 2011
- Effect of paclitaxel elution from reservoirs with bioabsorbable polymer compared to a bare metal stent for the elective percutaneous treatment of de novo coronary stenosis: the EUROSTAR-II randomised clinical trialEuroIntervention, 2011
- Paclitaxel Inhibits Ureteral Smooth Muscle Cell Proliferation and Collagen Production in the Absence of Cell ToxicityJournal of Urology, 2011
- Subglottic Stenosis Examined as a Fibrotic Response to Airway Injury Characterized by Altered Mucosal Fibroblast ActivityJAMA Otolaryngology–Head & Neck Surgery, 2010
- Complications of Silicone Stent Insertion in Patients With Expiratory Central Airway CollapseThe Annals of Thoracic Surgery, 2007
- Controlled release of sirolimus from a multilayered PLGA stent matrixBiomaterials, 2006
- Survival of Endothelial Cells in vitro on Paclitaxel-loaded Coronary StentsJournal of Biomaterials Applications, 2005
- Controlled release of paclitaxel from microemulsion containing PLGA and evaluation of anti-tumor activity in vitro and in vivoInternational Journal of Pharmaceutics, 2004
- New Tubular Bioabsorbable Knitted Airway Stent: Feasibility Assessment for Delivery and Deployment in a Dog ModelThe Annals of Thoracic Surgery, 2004
- Molecular responses of vascular smooth muscle cells to paclitaxel‐eluting bioresorbable stent materialsJournal of Biomedical Materials Research Part A, 2004