A novel retractable laparoscopic device for mapping gastrointestinal slow wave propagation patterns
- 29 April 2016
- journal article
- research article
- Published by Springer Nature in Surgical Endoscopy
- Vol. 31 (1) , 477-486
Abstract
Background Gastric slow waves regulate peristalsis, and gastric dysrhythmias have been implicated in functional motility disorders. To accurately define slow wave patterns, it is currently necessary to collect high-resolution serosal recordings during open surgery. We therefore developed a novel gastric slow wave mapping device for use during laparoscopic procedures. Methods The device consists of a retractable catheter constructed of a flexible nitinol core coated with Pebax. Once deployed through a 5-mm laparoscopic port, the spiral head is revealed with 32 electrodes at 5 mm intervals. Recordings were validated against a reference electrode array in pigs and tested in a human patient. Results Recordings from the device and a reference array in pigs were identical in frequency (2.6 cycles per minute; p = 0.91), and activation patterns and velocities were consistent (8.9 ± 0.2 vs 8.7 ± 0.1 mm s−1; p = 0.2). Device and reference amplitudes were comparable (1.3 ± 0.1 vs 1.4 ± 0.1 mV; p = 0.4), though the device signal-to-noise ratio was higher (17.5 ± 0.6 vs 12.8 ± 0.6 dB; P < 0.0001). In the human patient, corpus slow waves were recorded and mapped (frequency 2.7 ± 0.03 cycles per minute, amplitude 0.8 ± 0.4 mV, velocity 2.3 ± 0.9 mm s−1). Conclusion In conclusion, the novel laparoscopic device achieves high-quality serosal slow wave recordings. It can be used for laparoscopic diagnostic studies to document slow wave patterns in patients with gastric motility disorders.Keywords
Funding Information
- National Institute of Diabetes and Digestive and Kidney Diseases (DK64775)
- Health Research Council of New Zealand
- Alexander von Humboldt-Stiftung
- International Foundation for Functional Gastrointestinal Disorders
This publication has 43 references indexed in Scilit:
- Mapping and Modeling Gastrointestinal Bioelectricity: From Engineering Bench to BedsidePhysiology, 2013
- Electrogastrography: Methodology, Validation and ApplicationsJournal of Neurogastroenterology and Motility, 2013
- The gastrointestinal electrical mapping suite (GEMS): software for analyzing and visualizing high-resolution (multi-electrode) recordings in spatiotemporal detailBMC Gastroenterology, 2012
- High‐resolution spatial analysis of slow wave initiation and conduction in porcine gastric dysrhythmiaNeurogastroenterology & Motility, 2011
- A comparison of gold versus silver electrode contacts for high-resolution gastric electrical mapping using flexible printed circuit board arraysPhysiological Measurement, 2011
- Automated Gastric Slow Wave Cycle Partitioning and Visualization for High-resolution Activation Time MapsAnnals of Biomedical Engineering, 2010
- Origin and propagation of human gastric slow-wave activity defined by high-resolution mappingAmerican Journal of Physiology-Gastrointestinal and Liver Physiology, 2010
- High-resolution entrainment mapping of gastric pacing: a new analytical toolAmerican Journal of Physiology-Gastrointestinal and Liver Physiology, 2010
- Falling-Edge, Variable Threshold (FEVT) Method for the Automated Detection of Gastric Slow Wave Events in High-Resolution Serosal Electrode RecordingsAnnals of Biomedical Engineering, 2009
- Interstitial cells of Cajal in health and diseaseNeurogastroenterology & Motility, 2008