Microfluidic Electrochemical Array for Detection of Reactive Metabolites Formed by Cytochrome P450 Enzymes
- 31 October 2011
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 83 (24) , 9499-9506
Abstract
A novel, simple, rapid microfluidic array using bioelectronically driven cytochrome P450 enzyme catalysis for reactive metabolite screening is reported for the first time. The device incorporates an eight-electrode screen-printed carbon array coated with thin films of DNA, [Ru(bpy)2(PVP)10](ClO4) {RuPVP}, and rat liver microsomes (RLM) as enzyme sources. Catalysis features electron donation to cyt P450 reductase in the RLMs and subsequent cyt P450 reduction while flowing an oxygenated substrate solution past sensor electrodes. Metabolites react with DNA in the film if they are able, and damaged DNA is detected by catalytic square wave voltammetry (SWV) utilizing the RuPVP polymer. The microfluidic device was tested for a set of common pollutants known to form DNA-reactive metabolites. Logarithmic turnover rates based on SWV responses gave excellent correlation with the rodent liver TD50 toxicity metric, supporting the utility of the device for toxicity screening. The microfluidic array gave much better S/N and reproducibility than single-electrode sensors based on similar principles.Keywords
This publication has 55 references indexed in Scilit:
- Microfluidic electrochemical immunoarray for ultrasensitive detection of two cancer biomarker proteins in serumBiosensors and Bioelectronics, 2011
- Evaluation of Electrochemiluminescent Metabolic Toxicity Screening Arrays Using a Multiple Compound SetAnalytical Chemistry, 2011
- Efficient Bioelectronic Actuation of the Natural Catalytic Pathway of Human Metabolic Cytochrome P450sJournal of the American Chemical Society, 2011
- High-Throughput Metabolic Toxicity Screening Using Magnetic Biocolloid Reactors and LC−MS/MSAnalytical Chemistry, 2010
- Rapid LC-MS Drug Metabolite Profiling Using Microsomal Enzyme Bioreactors in a Parallel Processing FormatAnalytical Chemistry, 2009
- Comparison of DNA‐Reactive Metabolites from Nitrosamine and Styrene Using Voltammetric DNA/Microsomes SensorsElectroanalysis, 2009
- Synergistic Metabolic Toxicity Screening Using Microsome/DNA Electrochemiluminescent Arrays and NanoreactorsAnalytical Chemistry, 2008
- Electrochemiluminescent/voltammetric toxicity screening sensor using enzyme-generated DNA damageBiosensors and Bioelectronics, 2007
- Thin film voltammetry of metabolic enzymes in rat liver microsomesElectrochemistry Communications, 2007
- Electrochemiluminescent Arrays for Cytochrome P450-Activated Genotoxicity Screening. DNA Damage from Benzo[a]pyrene MetabolitesAnalytical Chemistry, 2007