Range-ambiguity artifacts (RAAs) are an erroneous mapping of returning echoes into a composite picture. The purpose of this review was to illustrate the mechanism of RAAs and to present the diagnostic problems caused by RAAs. RAA features differ slightly from organ to organ. At the level of the urinary bladder, RAAs take the form of a cloud-like, ill-demarcated, immobile, echogenic area, and the depth of the echogenic area differs depending on the pulse repetition frequency (PRF). This form is referred to as “static RAA” in this review. There are two key ultrasound characteristics of RAAs at the level of the liver: (a) the depth of RAAs change according to the PRF, and (b) RAAs move in accordance with the cardiac cycle. This form is referred to as “mobile RAA” in this review. At the level of the gallbladder, RAAs take the form of fine echogenic lines in the gallbladder. This phenomenon is actually a combination of two phenomena: a ring-down artifact and RAA. This form is referred to as “complex RAA (searchlight phenomenon)” in this review. The easiest way to reduce RAAs is to change the image depth. Sufficient knowledge of RAAs can prevent misdiagnosis of erroneously displayed returning echoes as real pathologic changes.Keywords
This publication has 21 references indexed in Scilit:
- Searchlight phenomenon: a novel artifact of the gallbladderJournal of Medical Ultrasonics, 2016
- Mirror Image Artifact Mimicking Heterotopic Pregnancy on Transvaginal Ultrasound: Case SeriesWestern Journal of Emergency Medicine, 2014
- Mobile echoes in liver cysts: A form of range‐ambiguity artifactJournal of Clinical Ultrasound, 2010
- US ArtifactsRadioGraphics, 2009
- Contrast-enhanced sonographic findings in a case of hepatobiliary cystadenoma with intracystic bleedingJournal of Clinical Ultrasound, 2006
- Analysis of posterior echoes using reconstructed vertical ultrasound imagesJournal of Medical Ultrasonics, 2006
- Analysis of refractive artifacts by reconstructed three-dimensional ultrasound imagingJournal of Medical Ultrasonics, 2006
- Acoustic artifacts and reverberation shadows in gallbladder sonograms: Their cause and clinical implicationsGastrointestinal Radiology, 1990
- Range ambiguities in real‐time ultrasoundJournal of Clinical Ultrasound, 1981
- Acoustic shadow formation by gallstones.Radiology, 1980