Reversible Hydration Composite Films for Evaporative Perspiration Control and Heat Stress Management
Authors:
Abstract
Donning of personal protective equipment (PPE) in the healthcare sector has been intensified by the on‐going COVID‐19 pandemic around the globe. While extensive PPE provides protection, it typically limits moisture permeability and severely hinders the sweat evaporation process, resulting in greater heat stress on the personnel. Herein, a zinc‐poly(vinyl alcohol) (Zn‐PVA) composite film is fabricated by embedding a super‐hygroscopic zinc‐ethanolamine complex (Zn‐complex) in the PVA matrix. By attaching the Zn‐PVA composite film, the relative humidity (RH) inside the protective suit decreases from 91.0% to 48.2%. The reduced RH level, in turn, enhances evaporative cooling, hence bringing down the heat index from 64.6 to 40.0 °C at an air temperature of 35 °C, remarkably lowering the likelihood of heat stroke. The American Society for Testing and Materials tests conducted on a sweating manikin have also proven that the Zn‐PVA composite films can significantly reduce the evaporative resistance of the protective suit by 90%. The low material cost, facile fabrication process, and reusability allow the Zn‐PVA composition films to be readily available for healthcare workers worldwide. This application can be further extended to other occupations that are facing severe thermal discomfort and heat stress.Keywords
This publication has 44 references indexed in Scilit:
- Methods to Calculate the Heat Index as an Exposure Metric in Environmental Health ResearchEnvironmental Health Perspectives, 2013
- Fabrication of a ZnO nanocolumnar thin film on a glass slide and its reversible switching from a superhydrophobic to a superhydrophilic stateRSC Advances, 2013
- Cooling effect of MWCNT-containing composite coatings on cotton fabricsThe Journal of the Textile Institute, 2013
- The torso cooling of vests incorporated with phase change materials: a sweat evaporation perspectiveTextile Research Journal, 2012
- Moisture‐induced effects on the tensile mechanical properties and glass‐transition temperature of poly(vinyl alcohol) filmsJournal of Applied Polymer Science, 2011
- A biodegradable and biocompatible PVA–citric acid polyester with potential applications as matrix for vascular tissue engineeringJournal of Materials Science: Materials in Medicine, 2008
- Adsorption of Water Vapor on Silica, Alumina, and Their Mixed Oxide AerogelsJournal of Chemical & Engineering Data, 2001
- Interaction between water and hydrophilic polymersThermochimica Acta, 1998
- Lack of a Predominant Adsorption of Water Vapor on Carbon MesoporesLangmuir, 1997
- Protective clothing and heat stressErgonomics, 1995