Neuromusculoskeletal Model Calibration Significantly Affects Predicted Knee Contact Forces for Walking
- 13 June 2016
- journal article
- Published by Wiley in Journal of Biomechanical Engineering
- Vol. 138 (8) , 081001-08100111
Abstract
Though walking impairments are prevalent in society, clinical treatments are often ineffective at restoring lost function. For this reason, researchers have begun to explore the use of patient-specific computational walking models to develop more effective treatments. However, the accuracy with which models can predict internal body forces in muscles and across joints depends on how well relevant model parameter values can be calibrated for the patient. This study investigated how knowledge of internal knee contact forces affects calibration of neuromusculoskeletal model parameter values and subsequent prediction of internal knee contact and leg muscle forces during walking. Model calibration was performed using a novel two-level optimization procedure applied to six normal walking trials from the Fourth Grand Challenge Competition to Predict In Vivo Knee Loads. The outer-level optimization adjusted time-invariant model parameter values to minimize passive muscle forces, reserve actuator moments, and model parameter value changes with (Approach A) and without (Approach B) tracking of experimental knee contact forces. Using the current guess for model parameter values but no knee contact force information, the inner-level optimization predicted time-varying muscle activations that were close to experimental muscle synergy patterns and consistent with the experimental inverse dynamic loads (both approaches). For all the six gait trials, Approach A predicted knee contact forces with high accuracy for both compartments (average correlation coefficient r = 0.99 and root mean square error (RMSE) = 52.6 N medial; average r = 0.95 and RMSE = 56.6 N lateral). In contrast, Approach B overpredicted contact force magnitude for both compartments (average RMSE = 323 N medial and 348 N lateral) and poorly matched contact force shape for the lateral compartment (average r = 0.90 medial and −0.10 lateral). Approach B had statistically higher lateral muscle forces and lateral optimal muscle fiber lengths but lower medial, central, and lateral normalized muscle fiber lengths compared to Approach A. These findings suggest that poorly calibrated model parameter values may be a major factor limiting the ability of neuromusculoskeletal models to predict knee contact and leg muscle forces accurately for walking.Keywords
This publication has 48 references indexed in Scilit:
- EMG-Driven Forward-Dynamic Estimation of Muscle Force and Joint Moment about Multiple Degrees of Freedom in the Human Lower ExtremityPLOS ONE, 2012
- Years lived with disability (YLDs) for 1160 sequelae of 289 diseases and injuries 1990–2010: a systematic analysis for the Global Burden of Disease Study 2010The Lancet, 2012
- Sensitivity of model predictions of muscle function to changes in moment arms and muscle–tendon properties: A Monte-Carlo analysisJournal of Biomechanics, 2012
- Fibre operating lengths of human lower limb muscles during walkingPhilosophical Transactions of the Royal Society B: Biological Sciences, 2011
- A Model of the Lower Limb for Analysis of Human MovementAnnals of Biomedical Engineering, 2009
- An EMG-driven model to estimate muscle forces and joint moments in stroke patientsComputers in Biology and Medicine, 2009
- Overground Physical Therapy Gait Training for Chronic Stroke Patients With Mobility DeficitsStroke, 2009
- Knee muscle forces during walking and running in patellofemoral pain patients and pain-free controlsJournal of Biomechanics, 2009
- Epidemiology of Gait Disorders in Community‐Residing Older AdultsJournal of the American Geriatrics Society, 2005
- Myofibrils Bear Most of the Resting Tension in Frog Skeletal MuscleScience, 1985