Usage of high‐performance mattresses for transport of Indo‐Pacific bottlenose dolphin
Authors:
- 19 June 2008
- journal article
- technical report
- Published by Wiley in Zoo Biology
- Vol. 27 (4) , 331-340
Abstract
Ground transport can be a stressful operation for dolphins if the long period of restraint causes damage to internal organs, especially to the lung, generated by their own weight. Buoyancy is deprived from dolphins under moist transport, in which dolphins are transported on mattresses. Upgrading mattresses is an effective way to modify the transportation method so as to compensate for the loss of buoyancy. In Indo‐Pacific bottlenose dolphins (Tursiops aduncus), we tried to find mattresses that performed well at distributing the dolphins' weight and preserved their pulmonary function. When using EV‐17 (thickness, 50 mm) put on EE‐20 (thickness, 50 mm), a wider support area, less extreme changes in pressure, and lower maximum pressures were observed compared with other mattress systems tested. On this mattress system, lower breathing rates, lower heart rates, and higher exhaled CO2 concentrations were shown compared with using standard mattresses. These results suggest that the performance of the combination of EV‐17 and EE‐20 is better than that of the standard mattress in terms of the cardiopulmonary function of dolphins. Zoo Biol 27:331–340, 2008.Keywords
This publication has 11 references indexed in Scilit:
- Relationship between Transportation Stress and Polymorphonuclear Cell Functions of Bottlenose Dolphins, Tursiops truncatusJournal of Veterinary Medical Science, 2007
- Biomechanical evaluation of four different mattressesApplied Ergonomics, 2006
- Economic assessment of pressure sore prevention using a computerized mattress system in patients with spinal cord injuryDisability and Rehabilitation, 2005
- Pressure Ulcer PreventionJournal of Long-Term Effects of Medical Implants, 2004
- Diurnal and annual changes in serum cortisol concentrations in Indo-Pacific bottlenose dolphins Tursiops aduncus and killer whales Orcinus orcaGeneral and Comparative Endocrinology, 2003
- Marine Mammal Transport2001
- An Integrative Review of Pressure Relief in Surgical PatientsAORN Journal, 2001
- The effect of position and mattress on interface pressureApplied Nursing Research, 2000
- Mattress evaluation—assessment of contact pressure, comfort and discomfortApplied Ergonomics, 1998
- Adaptive Changes in Hematologic and Plasma Chemical Constituents in Captive Beluga Whales, Delphinapterus leucasCanadian Journal of Fisheries and Aquatic Sciences, 1989