An Eight-Channel Phased Array RF Coil for Spine MR Imaging at 7 T
Authors:
- Oliver KraffOKOliver Kraff
- Andreas K. BitzABAndreas K. Bitz
- Stefan KruszonaSKStefan Kruszona
- Stephan OrzadaSOStephan Orzada
- Lena C. SchaeferLSLena C. Schaefer
- Jens M. TheysohnJTJens M. Theysohn
- Stefan MaderwaldSMStefan Maderwald
- Mark E. LaddMLMark E. Ladd
- Harald H. QuickHQHarald H. Quick
- 1 November 2009
- journal article
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 44 (11) , 734-740
Abstract
To develop a transmit/receive radiofrequency (RF) array for MR imaging of the human spine at 7 T. The prototype is characterized in simulations and bench measurements, and the feasibility of high-resolution spinal cord imaging at 7 T is demonstrated in in vivo images of volunteers. The RF phased array consists of 8 overlapping surface loop coils with a dimension of 12 cm x 12 cm each. Bench measurements were obtained with a phantom made of body-simulating liquid and assessed with a network analyzer. For safety validation, numerical computations of the RF field distribution and the corresponding specific absorption rate were performed on the basis of 3 different human body models. In vivo images of 3 volunteers (2 with a documented scoliosis) were acquired using a 3D-FLASH sequence with a high spatial resolution of 0.57 mm isotropic. The 7 T transmit/receive RF coil could be easily integrated into the patient table for examinations of the cervicothoracic or thoracolumbosacral spine. Comparable results were found for all 3 numerical calculations using different human body models. Measurements of the g-factor indicated good image quality for parallel imaging acceleration factors up to 2.7 along the head-feet direction, which could be validated in the in vivo images. The in vivo images demonstrated very fine anatomic features such as the longitudinal ligaments or the venous drainage through the vertebral bodies. A largely homogeneous excitation over an extensive field-of-view of 40 cm could be obtained. These early results indicate that a multichannel transmit/receive phased array RF coil can be used for in vivo spine imaging at 7 T, thereby rendering high-resolution spine imaging a promising new application in 7 T clinical research.Keywords
This publication has 32 references indexed in Scilit:
- A Comparison of 3T and 7T in the Detection of Small Parenchymal Veins Within MS LesionsInvestigative Radiology, 2009
- Imaging of the Musculoskeletal System In Vivo Using Ultra-high Field Magnetic Resonance at 7 TInvestigative Radiology, 2009
- First Clinical Study on Ultra-High-Field MR Imaging in Patients with Multiple Sclerosis: Comparison of 1.5T and 7TAmerican Journal of Neuroradiology, 2009
- MRI in multiple sclerosis: current status and future prospectsThe Lancet Neurology, 2008
- Does high field MRI allow an earlier diagnosis of multiple sclerosis?Journal of Neurology, 2008
- Magnetic field and tissue dependencies of human brain longitudinal 1H2O relaxation in vivoMagnetic Resonance in Medicine, 2007
- MR Imaging of the Spine at 3TMagnetic Resonance Imaging Clinics of North America, 2006
- Clinical 3T MR Imaging: Mastering the ChallengesMagnetic Resonance Imaging Clinics of North America, 2006
- High‐field magnetic resonance imaging of brain iron: birth of a biomarker?NMR in Biomedicine, 2004
- Spinal cord abnormalities in recently diagnosed MS patientsNeurology, 2004