Application of Fiber Bragg Grating Sensor System for Simulation Detection of the Heart Rate
Authors:
Open Access
- 1 October 2021
- conference paper
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 2049 (1) , 012002
Abstract
Fiber Bragg grating (FBG) is also widely used to detect the heart because it can be received in the form of pressure that results in changes in strain. FBG was chosen because it has a high sensitivity to strain. Heart rate detection can be done in several ways such as using a telescope, but using FBG has a high degree of accuracy and is sensitive to strain. Heart detection is still developing because of the serious problem with human life behavior so that efforts are needed to find other ways to more easily detect the heart. Currently, heart detection can be done without having to go to the hospital, such as by using a cellphone, watch, and others. This study aims to design and measure changes in the output power of FBG and to analyze the effect of strain change on FBG by loudspeaker vibration. The Bragg wavelengths used are 1310 nm and 1550 nm with a power of 1 mW as a diode laser source and the output is measured by an optical power meter. The highest change in output power at a wavelength of 1310 nm Bragg is equal to 0.471 μW, while at a wavelength of 1550 nm it is equal to 0.032 μW. The highest shift of the Bragg wavelength is at the Bragg 1310 nm wavelength, which is 0.598 nm, while the Bragg wavelength of 1550 nm is 0.552 nm. The highest change in strain was at 1310 nm Bragg wavelength valued at 576.186 με, while at 1550 nm Bragg wavelength was 432.113 με. This shows that the response at the Bragg wavelength of 1310 nm is more sensitive than the Bragg wavelength of 1550 nm.Keywords
This publication has 18 references indexed in Scilit:
- A single eye 3D image perception device using vertical double ring resonator constructionMicrowave and Optical Technology Letters, 2015
- Laser-Induced Graphite Plasma Kinetic Spectroscopy under Different Ambient PressuresChinese Physics Letters, 2015
- Algorithm for heart rate extraction in a novel wearable acoustic sensorHealthcare Technology Letters, 2015
- Fiber Bragg grating-based sensor for monitoring respiration and heart activity during magnetic resonance imaging examinationsJournal of Biomedical Optics, 2013
- Monitoring Respiration and Cardiac Activity Using Fiber Bragg Grating-Based SensorIEEE Transactions on Biomedical Engineering, 2012
- Radiation Self Absorption Effect in Ar Gas NX2 Mather Type Plasma FocusProcedia Engineering, 2011
- Coal Mine Disaster Rescue Life Sign Monitoring Technology Based on FBG and Acceleration SensorProcedia Engineering, 2011
- Respiration and body movement analysis during sleep in bed using hetero-core fiber optic pressure sensors without constraint to human activityJournal of Biomedical Optics, 2011
- Simplified coupling power model for fibers fusionOpto-Electronics Review, 2009
- Broadband single-mode operation of standard optical fibers by using a sub-wavelength optical wire filterOptics Express, 2008