Algorithmic corrections for localization microscopy with sCMOS cameras - characterisation of a computationally efficient localization approach
Open Access
- 10 May 2017
- journal article
- Published by Optica Publishing Group in Optics Express
- Vol. 25 (10) , 11701-11716
Abstract
Modern sCMOS cameras are attractive for single molecule localization microscopy (SMLM) due to their high speed but suffer from pixel non-uniformities that can affect localization precision and accuracy. We present a simplified sCMOS non-uniform noise model that incorporates pixel specific read-noise, offset and sensitivity variation. Using this model we develop a new weighted least squared (WLS) fitting method designed to remove the effect of sCMOS pixel non-uniformities. Simulations with the sCMOS noise model, performed to test under which conditions sCMOS specific localization corrections are required, suggested that pixel specific offsets should always be removed. In many applications with thick biological samples photon fluxes are sufficiently high that corrections of read-noise and sensitivity correction may be neglected. When correction is required, e.g. during fast imaging in thin samples, our WLS fit procedure recovered the performance of an equivalent sensor with uniform pixel properties and the fit estimates also attained the Cramer-Rao lower bound. Experiments with sub-resolution beads and a DNA origami test sample confirmed the results of the simulations. The WLS localization procedure is fast to converge, compatible with 2D, 3D and multi-emitter localization and thus provides a computationally efficient sCMOS localization approach compatible with most SMLM modalities.Keywords
Funding Information
- Engineering and Physical Sciences Research Council (EPSRC) (EP/N008235/1)
- Human Frontier Science Program (HFSP) (RGP0027/2013)
This publication has 20 references indexed in Scilit:
- Optical imaging of individual biomolecules in densely packed clustersNature Nanotechnology, 2016
- Optical Nanoscopy: From Acquisition to AnalysisAnnual Review of Biomedical Engineering, 2012
- Direct stochastic optical reconstruction microscopy with standard fluorescent probesNature Protocols, 2011
- 4D Super-Resolution Microscopy with Conventional Fluorophores and Single Wavelength Excitation in Optically Thick Cells and TissuesPLOS ONE, 2011
- Live-cell photoactivated localization microscopy of nanoscale adhesion dynamicsNature Methods, 2008
- Ultra-High Resolution Imaging by Fluorescence Photoactivation Localization MicroscopyBiophysical Journal, 2006
- Imaging Intracellular Fluorescent Proteins at Nanometer ResolutionScience, 2006
- Sub-diffraction-limit imaging by stochastic optical reconstruction microscopy (STORM)Nature Methods, 2006
- Surpassing the lateral resolution limit by a factor of two using structured illumination microscopyJournal of Microscopy, 2000
- Breaking the diffraction resolution limit by stimulated emission: stimulated-emission-depletion fluorescence microscopyOptics Letters, 1994