Reliability of Tunnel Measurements and the Quadrant Method Using Fluoroscopic Radiographs After Anterior Cruciate Ligament Reconstruction
Authors:
- Brian R. WolfBWBrian R. Wolf
- Kurt S. SpindlerKSKurt S. Spindler
- Warren R. DunnWDWarren R. Dunn
- James L. CareyJCJames L. Carey
- Charles L. CoxCCCharles L. Cox
- Jack T. AndrishJAJack T. Andrish
- 7 September 2012
- journal article
- Published by SAGE Publications in The American Journal of Sports Medicine
- Vol. 40 (10) , 2236-2241
Abstract
Background: Anterior cruciate ligament (ACL) reconstruction tunnel placement is often evaluated by radiographs. This study examines the interobserver reliability of various radiographic measurements of ACL tunnels. Hypothesis: When ideal radiographic views are obtained, the interobserver reliability of the measurements among experienced surgeons would be good to excellent. Study Design: Descriptive laboratory study. Methods: Tunnels for single-bundle ACL reconstruction were drilled and filled with metal interference screws or a tibial reamer on 73 cadaveric knees. Ideal fluoroscopic radiographs were obtained. Three independent reviewers performed 18 measurements including a modification of the grid method. For the grid method analysis, reviewers fit a 16 × 12 grid to the lateral knee radiograph, and the center of the femoral tunnel was marked. Interobserver reliability of the measurements was performed using intraclass correlation coefficients (ICCs). A precision grouping analysis was performed for the grid measurements to calculate the mean radius and standard deviation grouping distances. Results: The ICCs were excellent (>.75) for the tibial tunnel angles and tunnel measurements, the clock face measurement, and the Aglietti et al and Jonsson et al measurements. The ICCs were good (.4-.75) for an estimation of graft impingement, Harner et al measurements, and notch height. The mean radius for grid measurements was 0.6 ± 0.4 units (range, 0-2.36 units), with each unit being 1 box in the 16 × 12 grid. When a circle was constructed with a 1.3-unit radius, 95% of the 3 surgeons’ measurements would be included in the area of that circle. Conclusion: Reliability of ACL tunnel measurements was good to excellent under ideal circumstances for the majority of measurements. The modified grid method demonstrated very acceptable reliability. Clinical Relevance: Measurements with good to excellent reliability can be used to evaluate ACL tunnel placement when ideal radiographic views are obtained.Keywords
This publication has 18 references indexed in Scilit:
- Femoral attachment of the anterior cruciate ligamentKnee Surgery, Sports Traumatology, Arthroscopy, 2005
- Postoperative evaluation of femoral tunnel position in ACL reconstruction: plain radiography versus computed tomographyKnee Surgery, Sports Traumatology, Arthroscopy, 2005
- Femoral Tunnel Position in Anterior Cruciate Ligament Reconstruction Using Three Techniques. A Cadaver StudyArthroscopy, 1999
- Current Concepts Review - The Science of Reconstruction of the Anterior Cruciate Ligament*Journal of Bone and Joint Surgery, 1997
- Arthroscopic‐assisted anterior cruciate ligament reconstruction with the central third patellar tendonKnee Surgery, Sports Traumatology, Arthroscopy, 1997
- Revision Anterior Cruciate Ligament Surgery: Experience From PittsburghClinical Orthopaedics and Related Research, 1996
- Anterior cruciate ligament reconstruction: Endoscopic versus two‐incision techniqueArthroscopy, 1994
- Proceedings of the ESSKA Scientific Workshop on Reconstruction of the Anterior and Posterior Cruciate LigamentsKnee Surgery, Sports Traumatology, Arthroscopy, 1994
- Failure of reconstruction of the anterior cruciate ligament due to impingement by the intercondylar roof.Journal of Bone and Joint Surgery, 1993
- The Equivalence of Weighted Kappa and the Intraclass Correlation Coefficient as Measures of ReliabilityEducational and Psychological Measurement, 1973