3D‐printed patient‐specific instrumentation and the freehand technique in high‐tibial osteotomy: A prospective cohort‐comparative study in an outpatient setting
Open Access
- 20 January 2025
- journal article
- research article
- Published by Wiley in Journal of Experimental Orthopaedics
- Vol. 12 (1) , e70088
Abstract
Purpose: Tibial valgus osteotomy has shown to be a successful and cost‐effective procedure. The advent of image processing and three‐dimensional (3D) printing is an interesting tool for achieving more accurate and reproducible results. The aim of our study was to compare the accuracy of the conventional technique and the use of customized guides in the correction of tibial deformities in tibial varus patients, the surgical and clinical benefits, and the impact of treatment in the outpatient setting.Methods: A prospective cohort of 30 patients who underwent tibial valgus osteotomy were selected and randomized into two groups (3D‐printed guidewires and conventional techniques). All patients underwent a complete radiological study to plan the surgical procedure. During the surgical procedure, the surgical time and X‐ray exposure were analysed. The following results were evaluated: surgical time and X‐ray exposure, the correlation between the planned correction and the correction obtained at 3 post‐operative months, pre‐ and post‐operative knee injury and osteoarthritis outcome score (KOOS) value at 3 and 12 months, and differences between the two groups in terms of the correction obtained.Results: Radiation exposure in the ‘3D‐guide’ group was significantly different (8 [±4.51], p < 0.05), whereas surgical time was not significantly different between the control and guide 3D groups (60.69 [±8.89] and 53.43 [±11.69], respectively). At the 3‐month follow‐up, the post‐operative hip–knee–ankle and post‐operative mechanical–proximal–tibial angle were not significantly different (p > 0.05). At 3‐ and 12‐month post‐surgery, the Knee Injury and Osteoarthritis Outcome Score (KOOS) did not significantly differ between the conventional technique and the 3D‐guide technique (p > 0.05). The KOOS at 3 months were 87.86 (±5.64) for the control group and 88.46 (±3.53) for the 3D‐guide group, while at 12 months they were 91.5 (±5.72) for the control group and 88.57 (±8.81) for the 3D‐guide group.Conclusion: Customized 3D‐printed guides do not permit better correction or functional results than the conventional technique; rather, they reduce surgical time and intraoperative radiation exposure.Level of Evidence: II.Keywords
This publication has 33 references indexed in Scilit:
- 3D Surgical Printing Cutting Guides for Open-Wedge High Tibial Osteotomy: Do It YourselfThe Journal of Knee Surgery, 2016
- Assessing Lower Limb Alignment: Comparison of Standard Knee Xray vs Long Leg View.2015
- Biomechanical Properties of a New Anatomical Locking Metal Block Plate for Opening Wedge High Tibial Osteotomy: Uniplane OsteotomyKnee Surgery & Related Research, 2014
- Survival and clinical outcome of isolated high tibial osteotomy and combined biological knee reconstructionThe Knee, 2013
- Results of high tibial osteotomy: review of the literatureInternational Orthopaedics, 2009
- Effective measurement of knee alignment using AP knee radiographsThe Knee, 2009
- A 12-28-Year Followup Study of Closing Wedge High Tibial OsteotomyClinical Orthopaedics and Related Research, 2006
- The Knee injury and Osteoarthritis Outcome Score (KOOS): from joint injury to osteoarthritisHealth and Quality of Life Outcomes, 2003
- The forty-five-degree posteroanterior flexion weight-bearing radiograph of the knee.Journal of Bone and Joint Surgery, 1988
- [X-ray classification and examination technics in gonarthrosis].1980