Four resonators based high sensitive terahertz metamaterial biosensor used for measuring concentration of protein
Authors:
- 2 January 2019
- journal article
- research article
- Published by IOP Publishing in Journal of Physics D: Applied Physics
- Vol. 52 (9) , 095105
Abstract
A terahertz (THz) metamaterial biosensor based on four identical resonators is experimentally demonstrated, and high sensitivity is achieved by exciting four synchronous inductor-capacitor oscillations in a unit cell. The effect of geometries on the resonance frequency of the sensor is investigated using the finite integration time domain method, and the simulated sensitivity is 85 GHz per refractive index unit. The biosensor sample is fabricated using a surface micromachining process and characterized by a THz time domain spectroscopy system combined with bovine serum albumin (BSA) solution as an analyte. The experimental results indicate that the resonance frequency shows distinct redshift when the concentration of BSA solution increases. When the concentration is high, up to 765 µ mol l −1 , the frequency shift reaches 50 GHz, and the measurable minimum concentration is low, down to 1.5 µ mol l −1 . The biosensor is small in shape, wide in measurable range, convenient in operation, and rapid in detection, which is of great significance for rapid concentration measurement, biomolecules detection, and disease diagnosis.Keywords
Funding Information
- National Natural Science Foundation of China (11574059, 61565004, 11774288)
- National Technology Major Special Project (2017ZX02101007-003)
- Natural Science Foundation of Guangxi Province (2017GXNSFBA198116)
- Foundation from Guangxi Key Laboratory of Automatic Detection Technology and Instrument (YQ14114)
- Innovation Project of Guangxi Graduate Education, China (2018YJCX70, 2018YJCX67, 2018YJCX74)
This publication has 29 references indexed in Scilit:
- Alkanethiol-functionalized terahertz metamaterial as label-free, highly-sensitive and specificbiosensorBiosensors and Bioelectronics, 2013
- Comparison of Serum Human Epididymis Protein 4 with Cancer Antigen 125 as a Tumor Marker in Patients with Malignant and Nonmalignant DiseasesClinical Chemistry, 2011
- Metamaterials on Paper as a Sensing PlatformAdvanced Materials, 2011
- Carbon Nanoparticle-Enhanced Immunoelectrochemical Detection for Protein Tumor Marker with Cadmium Sulfide BiotracersAnalytical Chemistry, 2009
- Compact continuous-wave subterahertz system for inspection applicationsApplied Physics Letters, 2005
- Label-free amplified bioaffinity detection using terahertz wave technologyBiosensors and Bioelectronics, 2004
- Composite Medium with Simultaneously Negative Permeability and PermittivityPhysical Review Letters, 2000
- Pulsed terahertz spectroscopy of DNA, bovine serum albumin and collagen between 0.1 and 2.0 THzChemical Physics Letters, 2000
- Magnetism from conductors and enhanced nonlinear phenomenaIEEE Transactions on Microwave Theory and Techniques, 1999
- Extremely Low Frequency Plasmons in Metallic MesostructuresPhysical Review Letters, 1996