Constrained Liner in Neurologic or Cognitively Impaired Patients Undergoing Primary THA
- 1 December 2010
- journal article
- research article
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 468 (12) , 3255-3262
Abstract
THA performed in patients with cognitive deficits or neuromuscular diseases has been associated with a high postoperative dislocation rate. The constrained liner reportedly provides stability in patients with recurrent dislocation. However, achieving stability could be offset by early loosening when used in patients with neurologic diseases. We therefore asked whether constrained liners had a higher risk of loosening when used in primary THA for patients with neurologic diseases. We retrospectively reviewed a 144 patients (164 hips) with neuromuscular disease who had a constrained polyethylene insert from 1999 to 2004 and compared them to another 120 patients (132 hips) with neuromuscular disease operated on immediately before this period (from 1994 to 1998) who had a conventional polyethylene insert. Thirty-three (25%) of the 132 hips without a constrained liner were known to have had at least one dislocation and 21 had revision for recurrent dislocation. Ten other hips had revision for loosening of the cup. The survival rate was 82% at 5 years and 77% at 10 years with revision due to recurrent dislocation or loosening of the cup as the endpoint. With a constrained liner, at minimum 5-year followup (mean, 7 years; range, 5–10 years), the incidence of complications, particularly dislocation, was decreased (three dislocations among 164 hips; 2%), with one revision for recurrent dislocation and one revision for loosening. This constrained acetabular component provides durable protection against dislocation without substantial increased loosening at midterm followup. Level III, therapeutic study. See the Guidelines for Authors for a complete description of levels of evidence.Keywords
This publication has 42 references indexed in Scilit:
- A constrained acetabular component for recurrent dislocationThe Journal of Bone and Joint Surgery. British volume, 2006
- Epidemiology of Dislocation after Total Hip ArthroplastyClinical Orthopaedics and Related Research, 2006
- Constrained total hip arthroplasty in a paediatric patient with cerebral palsy and painful dislocation of the hipThe Journal of Bone and Joint Surgery. British volume, 2006
- The Long-term Outcome of 755 Consecutive Constrained Acetabular Components in Total Hip ArthroplastyThe Journal of Arthroplasty, 2005
- Use of a Constrained Tripolar Acetabular Liner to Treat Intraoperative Instability and Postoperative Dislocation after Total Hip ArthroplastyClinical Orthopaedics and Related Research, 2004
- Closed Reduction of Constrained Total Hip ArthroplastyClinical Orthopaedics and Related Research, 2003
- Femoral head size is a risk factor for total hip luxationA study of 42,987 primary hip arthroplasties from the Norwegian Arthroplasty RegisterActa Orthopaedica, 2003
- Total hip replacement in patients with Parkinson's diseaseInternational Orthopaedics, 2002
- Constrained acetabular cup disassemblyThe Journal of Arthroplasty, 1994
- Constrained acetabular componentsThe Journal of Arthroplasty, 1994