Deswelling Kinetics of Color Tunable Poly(N-Isopropylacrylamide) Microgel-Based Etalons
Authors:
- 26 October 2011
- journal article
- research article
- Published by American Chemical Society (ACS) in The Journal of Physical Chemistry B
- Vol. 115 (49) , 14359-14368
Abstract
Poly(N-isopropylacrylamide) (pNIPAm) microgel-based etalons are optical materials fabricated by depositing a monolithic layer of microgels on a semitransparent Au film adhered to a glass coverslip, followed by the deposition of a second semitransparent Au layer over the microgel layer (overlayer). These materials exhibit characteristic colors and multipeak reflectance spectra, both of which depend on the distance between the Au surfaces (mediated by the microgel diameter) and the refractive index of the microgel layer. In this submission, the deswelling kinetics of pNIPAm microgel-based etalons are investigated by inducing microgel deswelling through exposure to a 30% methanol/H2O solution. Exposed to this solvent system, the transition temperature of the microgels is lowered to a temperature below the experimental temperature and the microgels comprising the etalon collapse. This collapse induces an etalon color change, which is observed as a blue shift in the reflectance spectrum. The kinetics of deswelling were shown to be strongly dependent on the thickness of the Au overlayer, e.g., thicker overlayers slow the solvent exchange and the resultant deswelling kinetics. Additionally, for thicker overlayers, the rate of deswelling increases with decreasing etalon size. Taken together, these results suggest that the kinetics depend strongly on the ability of the solvent to exchange from/to the microgel layer. For example, if the Au overlayer is thin, more solvent can exchange through the overlayer in a given amount of time compared to an etalon composed of a thick overlayer. Likewise, etalons of smaller dimensions have faster deswelling kinetics due to the shorter distance the solvent needs to travel laterally through the microgel layer to exchange. The results from this study are of fundamental importance but will be used to develop sensors with fast response times for point-of-care diagnostics.Keywords
This publication has 43 references indexed in Scilit:
- Integration of a Chemical‐Responsive Hydrogel into a Porous Silicon Photonic Sensor for Visual Colorimetric ReadoutAdvanced Functional Materials, 2010
- Point-of-Care Diagnostics for Global HealthAnnual Review of Biomedical Engineering, 2008
- Hydrogel‐Supported Optical‐Microcavity SensorsAdvanced Materials, 2005
- Diagnostics for the developing worldNature Reviews Microbiology, 2004
- High Ionic Strength Glucose-Sensing Photonic CrystalAnalytical Chemistry, 2003
- Trends in miniaturized total analysis systems for point-of-care testing in clinical chemistryLab on a Chip, 2001
- Identification of Gram Negative Bacteria Using Nanoscale Silicon MicrocavitiesJournal of the American Chemical Society, 2001
- Nanoscale microcavities for biomedical sensor applications2000
- Polymerized colloidal crystal hydrogel films as intelligent chemical sensing materialsNature, 1997
- DIPSTICK METHOD FOR HUMAN CHORIONIC GONADOTROPIN SUITABLE FOR EMERGENCY USE ON WHOLE BLOOD AND OTHER FLUIDSThe Lancet, 1985