The Guideliner™ Catheter for Stent Delivery in Difficult Cases: Tips and Tricks
- 17 October 2011
- journal article
- case report
- Published by Wiley in Journal of Interventional Cardiology
- Vol. 24 (5) , 450-461
Abstract
Introduction: Stent delivery in complex coronary anatomy with severe calcification and tortuosity is still a common cause of percutaneous coronary interventions (PCI) failure. Recently, a new support rapid exchange catheter, the Guideliner, has been designed specifically for device delivery. Methods: From June 2010 to December 2010, we performed 10 cases using the Guideliner catheter to improve backup support and facilitate stent delivery: 2 emergent PCI for ST elevation myocardial infarction, and 8 stable elective PCI. In 3 cases the operator chose the femoral access, in 2 cases crossover from radial to femoral access was needed, and the other cases were performed radially. In 2 cases PTCA with drug‐eluting balloon was performed; in the other cases second‐generation drug‐eluting stent was implanted. Results: One case, the first one, failed, as stent could not be delivered to the target lesion. The other 9 cases were performed successfully. Three proximal dissections were detected and sealed with stent implantation. In 2 cases, we had stent damage due to the passage of the stent through the Guideliner metal collar. Another stent had to be used. Conclusions: In our experience, the Guideliner catheter is safe to use and helps device delivery in difficult settings. We describe here our experience with the Guideliner catheter for stent delivery and backup support; we discuss its utility and drawbacks in acute and stable clinical settings. Moreover, the aim of this article is to help interventional cardiologists using the device in difficult lesions to avoid potential complications. (J Interven Cardiol 2011;24:450–461)Keywords
This publication has 8 references indexed in Scilit:
- The use of a guide catheter extension system as an aid during transradial percutaneous coronary intervention of coronary artery bypass graftsCatheterization and Cardiovascular Interventions, 2011
- Distal stent delivery with guideliner catheter: First in man experienceCatheterization and Cardiovascular Interventions, 2010
- The GuideLiner™ “child” catheterEuroIntervention, 2010
- Use of the Heartrail II catheter as a distal stent delivery device; an extended case seriesEuroIntervention, 2009
- Successful use of the Heartrail III catheter as a stent delivery catheter following failure of conventional techniquesCatheterization and Cardiovascular Interventions, 2008
- When one won't do it, use two—double “Buddy” wiring to facilitate stent advancement across a highly calcified arteryCatheterization and Cardiovascular Interventions, 2006
- Relation of percutaneous coronary intervention of complex lesions to clinical outcomes (from the NHLBI Dynamic Registry)The American Journal of Cardiology, 2002
- Successful stent delivery with deep seating of 6 French guiding catheters in difficult coronary anatomyCatheterization and Cardiovascular Interventions, 1999