Experimental Study on Improving the Strength and Ductility of Prefabricated Concrete Bridge Piers Using GFRP Tube Confinement
Open Access
Abstract
The application of precast assembled pier systems in high-seismicity regions is often constrained by their seismic performance limitations. To validate the optimization effect of GFRP confinement on the hysteretic performance of bridge piers, this study first conducted axial compression tests on 54 glass fiber-reinforced polymer (GFRP)-confined concrete cylindrical specimens. The investigation focused on the effects of fiber layers (6 and 10), orientation angles (, , ), slenderness ratios (2 and 4), and compression section configurations (fully loaded vs. core concrete loading only) on confinement efficacy. The experimental results demonstrate that specimens with fiber angles achieved an optimal balance between strength and ductility, exhibiting an average strength enhancement of 298.0% and a maximum axial strain of 2.7% compared to unconfined concrete. Subsequently, two GFRP tube-confined concrete bridge piers with varying fiber layers (PRCG1: 6 layers; PRCG2: 10 layers) and one unconfined reference pier (PRC) were designed and fabricated. All specimens employed grout-filled sleeves to connect caps and piers. Pseudo-static tests revealed that GFRP confinement effectively mitigated damage in plastic hinge zones and enhanced seismic performance. Compared to the PRC, PRCG1 and PRCG2 exhibited increases in ultimate displacement by 19.50% and 28.57%, in ductility coefficients by 18.56% and 27.84%, and in cumulative hysteretic energy dissipation by 13.90% and 26.43%, respectively. At the 5% drift ratio, their load capacities increased by 26.74% and 23.25%, stiffnesses improved by 28.91% and 25.51%, and residual displacements decreased by 20.89% and 11.17%. The accuracy and applicability of the GFRP tube-confined bridge pier model, developed based on the Lam–Teng model, were validated through numerical simulations using the OpenSees fiber element approach.
Keywords
Funding Information
- National Natural Science Foundation of China (52278189, 51878606, LGG22E080007, 202116, 202207)
- Zhejiang Province Basic Public Welfare Research Project (52278189, 51878606, LGG22E080007, 202116, 202207)
- Ningbo City Transportation Science and Technology Project (52278189, 51878606, LGG22E080007, 202116, 202207)
This publication has 25 references indexed in Scilit:
- Seismic behavior of FRP confined steel reinforced UHPC columnsStructures, 2025
- Seismic performance of precast segmental bridge columns repaired with CFRP wrapsComposite Structures, 2020
- Investigation of the stress-strain constitutive behavior of ±55° filament wound GFRP pipes in compression and tensionComposites Part B: Engineering, 2019
- Stress-strain model for FRP-confined concrete subject to arbitrary load pathComposites Part B: Engineering, 2019
- Cyclic performance and simplified pushover analyses of precast segmental concrete bridge columns with circular sectionEarthquake Engineering and Engineering Vibration, 2016
- Performance-based seismic design of unbonded precast post-tensioned concrete filled GFRP tube piersComposites Part B: Engineering, 2013
- Experimental testing and analytical modeling of CFRP-confined large circular RC columns subjected to cyclic axial compressionEngineering Structures, 2012
- Stress–strain model for FRP-confined concrete under cyclic axial compressionEngineering Structures, 2009
- Behavior and Modeling of Fiber Reinforced Polymer-Confined ConcreteJournal of Structural Engineering, 2004
- Design-oriented stress–strain model for FRP-confined concreteConstruction and Building Materials, 2003