High Resolution Self-Mixing Laser-Doppler Vibrometry with a Laser-Diode-Pumped Microchip LiNdP4O12 Laser

Authors:
  • KOKenju Otsuka
    Kenju Otsuka
  • TFTakeki Fukazawa
    Takeki Fukazawa
  • NSNobuatsu Sekita
    Nobuatsu Sekita
  • SHShin-Ichi Higashihara
    Shin-Ichi Higashihara

Abstract
A simple laser vibrometer system (LVS) has been built around a laser-diode-pumped microchip LiNdP4O12 (LNP) laser combined with an acousto-optic frequency shifter, using an efficient self-mixing modulation arising from the interference between a laser field and a weak field that is fed back from a rough vibrating target. The LVS provides a 50 dB carrier-to-noise ratio for 3 kHz bandwidth, even when monitoring parts that have extremely low reflectivity. Application to laser-Doppler-velocimetry (LDV) capable of discriminating the direction in which different targets are moving has been demonstrated. A remote-sensing experiment by optical fiber access to the target is described briefly.

This publication has 8 references indexed in Scilit: