Influence of Nd:YAG laser capsulotomy on toric intraocular lens rotation and change in cylinder power
- 1 January 2024
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 50 (1) , 43-50
Abstract
Purpose: To investigate toric monofocal intraocular lens (TIOL) rotation and associated changes in cylinder power caused by Nd:YAG laser capsulotomy performed due to posterior capsule opacification (PCO). Setting: Ekol Eye Hospital, Izmir, Turkey. Design: Prospective case series. Methods: 41 eyes of 20 women and 21 men were included in the study. Before and 1 month after Nd:YAG laser capsulotomy, TIOL tilt and decentration were determined with Scheimpflug camera, and TIOL axial rotation and the change in cylinder power induced by this rotation were measured by ray tracing aberrometry. The time interval between cataract surgery and Nd:YAG laser capsulotomy was noted. Results: Rotational misalignment of the TIOL was measured as 4.65 ± 2.75 degrees (range 0 to 11 degrees) before vs 6.97 ± 2.92 degrees (range 0 to 13 degrees) after capsulotomy, and absolute rotation was 2.75 ± 1.94 degrees (range 0 to 7 degrees, P = .028). Before and after Nd:YAG laser capsulotomy, cylinder power was 0.24 ± 0.70 diopter (D) (range 0.00 to 0.63 D) vs 0.56 ± 0.77 D (range 0.02 to 0.91 D), respectively, with an absolute change in cylinder power of 0.34 ± 0.22 D (range 0.01 to 0.90 D, P = .001). After capsulotomy, there was a significant decrease in IOL tilt in the horizontal and vertical planes and an increase in decentration (P < .05). Time interval (33.02 ± 12.9 months) and IOL horizontal decentration were independent factors affecting IOL rotation after capsulotomy (P < .05). Conclusions: Nd:YAG laser capsulotomy may cause TIOL rotation as well as tilt and decentration, resulting in a change in the TIOL's corrective effect on corneal astigmatism. Although this change was clinically insignificant, it may be beneficial to consider that TIOL rotational misalignment may occur in patients undergoing early capsulotomy.Keywords
This publication has 28 references indexed in Scilit:
- Comparison of Nd:YAG Laser Capsulotomy Rates Between Refractive Segmented Multifocal and Multifocal Toric Intraocular LensesAmerican Journal of Ophthalmology, 2021
- Astigmatism induced by intraocular lens tilt evaluated via ray tracingJournal of Cataract & Refractive Surgery, 2018
- Rotation of a toric intraocular lens from neodymium:YAG laser posterior capsulotomyJournal of Cataract & Refractive Surgery, 2018
- Toric Intraocular Lenses in the Correction of Astigmatism During Cataract SurgeryOphthalmology, 2016
- Toric vs Aspherical Control Intraocular Lenses in Patients With Cataract and Corneal AstigmatismJAMA Ophthalmology, 2014
- Long-term clinical outcomes of toric intraocular lens implantation in cataract cases with preexisting astigmatismJournal of Cataract & Refractive Surgery, 2014
- Rotational stability of a toric intraocular lens: Influence of axial length and alignment in the capsular bagJournal of Cataract & Refractive Surgery, 2012
- Long-term Staar Toric Intraocular Lens Rotational StabilityAmerican Journal of Ophthalmology, 2008
- Tilt and decentration of intraocular lenses in vivo from Purkinje and Scheimpflug imagingJournal of Cataract & Refractive Surgery, 2007
- Comparison of the stability of 1-piece and 3-piece acrylic intraocular lenses in the lens capsuleJournal of Cataract & Refractive Surgery, 2005