Data-Driven Evaluation of Power Quality in Hospital Electrical Systems: Case Study of University of Lampung, Indonesia
Authors:
- Gigih Forda NamaGNGigih Forda Nama
- Tugi YonoTYTugi Yono
Open Access
- 30 December 2025
- journal article
- Published by Seventh Sense Research Group Journals in International Journal of Electrical and Electronics Engineering
- Vol. 12 (12) , 104-116
Abstract
Reliability and continuity of electrical power supply are increasingly being recognized as essential for the effective functioning of contemporary healthcare services. Poor Power Quality (PQ) events can reduce the clinical usefulness of medical devices and jeopardize patient health, as well as incur high operating costs. This article reports an extensive PQ analysis at the University of Lampung Hospital (a health and academic services provider) in Indonesia. The research makes use of high-sampling-rate electrical datasets from four sets of data acquired on the Main Distribution Panel (MDP) in the hospital. Important PQ parameters, such as three-phase voltage and current, frequency, power factor, Voltage Unbalance Ratio (VUR), and Total Harmonic Distortion (THD), are systematically calculated. The approach is based on international norms and references for definitions (IEEE 1159), measurement methods (IEC 61000-4-30), and limits compliance (IEEE 519). The findings show stable voltage and frequency characteristics as expected from a good grid service utility. However, PQ problems of importance were observed in the internal distribution system of the hospital, such as voltage level imbalance lasting for longer than permitted in the standard (10%) and current harmonic distortion that was very high, which the Total Demand Distortion (TDD) surpassed many times over the IEEE 519 recommended values for hospitals. A somewhat lagging power factor was noted (indicating quite some loss in electrical efficiency). The present study offers a valuable empirical baseline and quantification of PQ challenges at an important healthcare facility in the planned University of Lampung Hospital. The results emphasize the risks of uncontrolled non-linear loads and confirm the importance of focused measures for load harmonization, such as active harmonic filtering systems and implementation of load equalization plans, which improve the quality, security, and efficiency of power supply in the hospital. For a real-time Internet of Things (IoT) monitoring application, according to the data from question 1, there is a strong positive correlation between electricity consumption and building operation schedule. Weekdays (Monday-Friday, 6:30 AM to 5:30 PM) always have the largest number of peak current loads, with a sharp decrease during weekends. Even though differences in phase were small, the mean voltage was just within the nominal limits.Keywords
This publication has 48 references indexed in Scilit:
- A Review to Diagnose Faults Related to Three-Phase Industrial Induction MotorsJournal of Failure Analysis and Prevention, 2022
- The power quality measurements and real time monitoring in distribution feedersMaterials Today: Proceedings, 2021
- AI and Machine Learning Paradigms for Health Monitoring System2021
- VFD Challenges for Shipboard Electrical Power System Design2019
- Alternative approaches and dynamic analysis considerations for detecting open phase conductors in three phase power systemsElectric Power Systems Research, 2018
- Overvoltage Mechanisms in Power Systems2018
- Monitoring of Vital Signs with Flexible and Wearable Medical DevicesAdvanced Materials, 2016
- Evidence management for compliance of critical systems with safety standards: A survey on the state of practiceInformation and Software Technology, 2015
- A simple power factor calculation for electrical power systemsInternational Journal of Electrical Power & Energy Systems, 2014
- Electrical Systems1996