Hydroxyapatite Femoral Stems for Total Hip Arthroplasty
Authors:
- 1 December 2001
- journal article
- section i-symposium
- Published by Wolters Kluwer Health in Clinical Orthopaedics and Related Research
- Vol. 393 (393) , 101-111
Abstract
Three hundred eighty hydroxyapatite-coated titanium alloy stems were implanted in a young and active patient population from 1987 through 1990. Within the population, 274 patients (314 hips) had a minimum 10-year and maximum 13-year followup. The average age of the population was 51 years. Thirty-seven percent of the population was 50 years or younger when operated on (average age, 39 years). Osteoarthritis was seen in 63.7% and avascular necrosis in 16.6% of patients. Fifty-four percent of patients were men. Clinically, these patients had early pain relief and rapid restoration of function. The Harris hip score averaged 92 points, and only 1.6% of patients had mild or moderate activity-related thigh pain. Radiographically, progressive remodeling occurred around the implants, 100% were bone stable, and no patient had endosteal distal osteolysis. Two patients had revision surgery for aseptic loosening: one at 2 years postoperative because of a nonunion of a concomitant subtrochanteric osteotomy and one at 9.5 years postoperative because of polyethylene wear and progressive osteolysis. The mechanical failure rate was 0.5%. The results show excellent lasting fixation of this tapered titanium alloy stem coated proximally with a thin, dense layer of hydroxyapatite. The stem has performed well in a young, active, high-risk population and in the hands of various surgeons.Keywords
This publication has 42 references indexed in Scilit:
- Rheumatoid arthritis and hydroxyapatite-coated hip prosthesesThe Journal of Arthroplasty, 1998
- Hydroxyapatite-Coated Total Hip Femoral Components in Patients Less Than Fifty Years Old. Clinical and Radiographic Results after Five to Eight Years of Follow-up*Journal of Bone and Joint Surgery, 1997
- Remodeling of Bone around Hydroxyapatite-Coated Femoral Stems*Journal of Bone and Joint Surgery, 1996
- The effect of operative fit and hydroxyapatite coating on the mechanical and biological response to porous implants.Journal of Bone and Joint Surgery, 1995
- The results of improved cementing techniques for total hip arthroplasty in patients less than fifty years old. A ten-year follow-up study.Journal of Bone and Joint Surgery, 1994
- Histomorphometric assessment of the mechanisms for rapid ingrowth of bone to HA/TCP coated implantsJournal of Biomedical Materials Research, 1993
- Hydroxylapatite coating of porous implants improves bone ingrowth and interface attachment strengthJournal of Biomedical Materials Research, 1992
- Improved cementing techniques and femoral component loosening in young patients with hip arthroplasty. A 12-year radiographic reviewThe Journal of Bone and Joint Surgery. British volume, 1992
- Plasma sprayed coatings of hydroxylapatiteJournal of Biomedical Materials Research, 1987
- Ectopic Ossification Following Total Hip ReplacementJournal of Bone and Joint Surgery, 1973